Key result
A multiphysics simulation environment integrating fluid-structure interaction and ultrasound simulation was developed to assess the accuracy of carotid strain estimates from ultrasonic wall tracking.
Why the study?
Does a 1-D ultrasonic wall tracking algorithm accurately estimate carotid strain compared to a multiphysics ground truth model?
Does a 1-D ultrasonic wall tracking algorithm accurately estimate carotid strain compared to a multiphysics ground truth model?
Ultrasonic wall tracking can estimate circumferential strain with reasonable accuracy in the common carotid artery, but it is unreliable for intra-arterial radial strain and underestimates the Young's modulus, suggesting caution in clinical interpretation.
Answers are grounded in this paper and cite their sources.
Ultrasonic wall tracking warrants caution for radial strain and modulus estimates; multiphysics simulation extends preclinical validation tools for carotid imaging.
We used a multiphysics model to assess the accuracy of carotid strain estimates derived from a 1-D ultrasonic wall tracking algorithm. The presented tool integrates fluid-structure interaction (FSI) simulations with an ultrasound simulator (Field II), which allows comparison of the ultrasound (US) images with a ground truth. Field II represents tissue as random points on which US waves reflect and whose position can be updated based on the flow field and vessel wall deformation from FSI. We simulated the RF-signal of a patient-specific carotid bifurcation, including the blood pool as well as the vessel wall and surrounding tissue. Distension estimates were obtained from a wall tracking algorithm using tracking points at various depths within the wall, and further processed to assess radial and circumferential strain. The simulated data demonstrated that circumferential strain can be estimated with reasonable accuracy (especially for the common carotid artery and at the lumen-intima and media-adventitia interface), but the technique does not allow to reliably assess intra-arterial radial strain. These findings were supported by in vivo data of 10 healthy adults, showing similar circumferential and radial strain profiles throughout the arterial wall. We concluded that these deviations are present due to the complex 3-D vessel wall deformation, the presence of specular reflections and, to a lesser extent, the spatially varying beam profile, with the error depending on the phase in the cardiac cycle and the scanning location.
No takes yet. Share an insight, caveat, or question.
Swillens et al. (2011) studied Carotid artery stenosis (simulation model) (n=1). Ultrasonic wall tracking (simulation) vs. True mechanical deformation from FSI-simulation was evaluated on Accuracy of ultrasonic estimation of radial and circumferential strain. A multiphysics simulation environment integrating fluid-structure interaction and ultrasound simulation was developed to assess the accuracy of carotid strain estimates from ultrasonic wall tracking.