Key result
Multicontrast delayed enhancement (MCDE) MRI significantly reduced variability in infarct gray zone size due to random noise and operator input compared to conventional IR-GRE analysis.
Why the study?
Does MCDE MRI reduce variability in infarct zone classification compared to IR-GRE DE-MRI in patients with chronic MI?
Cross-Sectional (n=15)
Does MCDE MRI reduce variability in infarct zone classification compared to IR-GRE DE-MRI in patients with chronic MI?
MCDE MRI with automated fuzzy clustering provides a more reproducible measure of infarct core and gray zones compared to conventional IR-GRE DE-MRI.
Answers are grounded in this paper and cite their sources.
MCDE MRI may offer more reproducible infarct gray zone measures in chronic MI; leaves open clinical utility pending prospective validation.
Delayed enhancement MRI (DE-MRI) can be used to identify myocardial infarct (MI). Classification of MI into the infarct core and heterogeneous periphery (called the gray zone) on conventional inversion-recovery gradient echo (IR-GRE) DE-MRI images has been related to inducibility for ventricular tachycardia. However, this classification is sensitive to image noise, depends on the signal intensity characteristics in a remote region of myocardium, and requires manual contours of the endocardial border. Image analysis and fuzzy clustering techniques were developed to analyze images acquired using a multicontrast delayed enhancement (MCDE) sequence in order characterize the infarct zones. The MCDE analysis is automated and uses data fitting of signal intensities acquired at multiple inversion times. In a study of 15 patients with chronic MI, the gray zones derived from IR-GRE and MCDE images were comparable. The variability in the gray zone size associated with random noise and operator input was significantly reduced using the MCDE-based analysis compared to the IR-GRE-based analysis. In summary, the MCDE approach yields a more reproducible measure of the infarct core and gray zones on any given data set.
No takes yet. Share an insight, caveat, or question.
Detsky et al. (2009) conducted a cross-sectional in Chronic myocardial infarction (n=15). Multicontrast delayed enhancement (MCDE) MRI with fuzzy clustering vs. Conventional inversion-recovery gradient echo (IR-GRE) DE-MRI was evaluated on Variability in gray zone size associated with random noise and operator input. Multicontrast delayed enhancement (MCDE) MRI significantly reduced variability in infarct gray zone size due to random noise and operator input compared to conventional IR-GRE analysis.