Key result
Longer MRI echo times reduce measured carotid wall thickness by ~9% via adventitial signal decay.
Why the study?
Does echo time impact carotid artery wall thickness measurements on MRI?
Cross-Sectional (n=65)
No
Does echo time impact carotid artery wall thickness measurements on MRI?
Carotid wall thickness measurements decrease with longer echo times due to the fast T2 relaxation time of the adventitia, indicating that short echo times are needed to accurately include the adventitia in measurements.
Answers are grounded in this paper and cite their sources.
Echo time selection influences carotid wall thickness quantification on MRI; supports protocol standardization in future studies.
PURPOSE: To investigate the impact of T2 relaxation of the carotid wall on measurements of its thickness. MATERIALS AND METHODS: The common carotid artery wall was imaged using a spin echo sequence acquired at four echo times (17 ms to 68 ms) in 65 participants as part of VALIDATE study. Images were acquired transverse to the artery 1.5 cm proximal to the flow divider. Mean wall thickness, mean wall signal intensity, lumen area, and outer wall area were measured for each echo. Contours were also traced on the image from the fourth echo and then propagated to the images from the preceding echoes. This was repeated using the image from the first echo. Mean wall signal intensity measurements at the four echo times were fit to a mono-exponential decay curve to derive the mean T2 relaxation time for each set of contours. RESULTS: Mean wall thickness decreased with increasing echo time, with an average thickness reduction of 8.6% between images acquired at the first and last echo times (TE) (0.93 mm at TE 17 ms versus 0.85 mm at TE 68 ms, P < 0.001). Average T2 relaxation time of the carotid wall decreased by 3% when the smaller contours from the last echo were used, which excluded the outer-most layer (54.3 ± 7.6 ms versus 52.7 ± 6.6 ms, P = 0.03). CONCLUSION: Carotid wall thickness measurements decrease with echo time as expected by the fast T2 relaxation time of the outer-most layer, namely the adventitia. A short echo time is needed for thickness measurements to include adventitia, which plays an important role in plaque development.
No takes yet. Share an insight, caveat, or question.
Qiao et al. (2012) conducted a cross-sectional in Healthy common carotid artery wall (subclinical atherosclerosis assessment) (n=65). Longer echo time (TE 68 ms) on 3T multi-echo spin-echo carotid MRI vs. Short echo time (TE 17 ms) on 3T multi-echo spin-echo carotid MRI was evaluated on Mean carotid artery wall thickness (mm) (MD -0.08 mm (8.6% reduction), p=<0.001). Increasing MRI echo time from 17 ms to 68 ms reduced measured mean carotid artery wall thickness by 8.6% due to fast T2 decay of the adventitia.
Synapse has enriched 10 related papers. Consider them for comparative context: