Complete A-V block is a frequent and highly lethal complication of acute myocardial infarction, with differing incidence and mortality depending on whether the infarct location is anterior or posterior.
of continuous elec- trocardiographic monitoring techniques has resulted in recognition that conduction disturbances occur more frequently in patients with acute myocardial infarction than was previously thought to be the case. Complete atrioventricular (A-V) block has been report- ed in up to 9% of patients who have had acute infarcts,1 and bundle-branch block has been recorded in 13% of cases.2 Complete A-V block is an especially important complication of acute infarction since it is associated with a higher mortality rate. For example, in a recent report by Kostuk and Beanlands, the mortality in 378 patients with acute myocardial infarc- tion was 20%, whereas in those patients who also developed complete A-V block the mortality was 50%.1 Important differences have been described between A-V block occurring during the course of acute posterior as contrasted with acute anterior infarction (table 1). A-V block occurs more frequently in patients with acute posterior wall infarction, but it is associated with a lower mortality rate than A-V block with acute anterior infarction. For example, Norris reported that out of 34 cases of second and third degree A-V block occurring in 276 patients with acute infarctions, 26 had a posterior and eight an anterior infarct.3
No takes yet. Share an insight, caveat, or question.
Hackel et al. (1971) studied this question.