Key result
A video-based deep learning model achieved an accuracy of 92% and an AUC of 0.90 for the automated detection of hypertensive cardiomyopathy from echocardiographic videos, outperforming the vanilla I3D model.
Why the study?
Manual detection of echocardiographic parameters for cardiac disease detection requires laborious steps and expertise.
Does a video-based deep learning method improve the detection of hypertensive cardiomyopathy from echocardiographic videos compared to image-based methods?
Observational (n=297)
No
Does a video-based deep learning method improve the detection of hypertensive cardiomyopathy from echocardiographic videos compared to image-based methods?
A weakly supervised video-based 3D convolutional neural network accurately detects hypertensive cardiomyopathy from echocardiographic videos, outperforming traditional image-based deep learning methods.
Supports video-based DL for hypertensive cardiomyopathy detection on echo; extends image-based methods but leaves open prospective validation.
INTRODUCTION: Parameters, such as left ventricular ejection fraction, peak strain dispersion, global longitudinal strain, etc. are influential and clinically interpretable for detection of cardiac disease, while manual detection requires laborious steps and expertise. In this study, we evaluated a video-based deep learning method that merely depends on echocardiographic videos from four apical chamber views of hypertensive cardiomyopathy detection. METHODS: One hundred eighty-five hypertensive cardiomyopathy (HTCM) patients and 112 healthy normal controls (N) were enrolled in this diagnostic study. We collected 297 de-identified subjects' echo videos for training and testing of an end-to-end video-based pipeline of snippet proposal, snippet feature extraction by a three-dimensional (3-D) convolutional neural network (CNN), a weakly-supervised temporally correlated feature ensemble, and a final classification module. The snippet proposal step requires a preliminarily trained end-systole and end-diastole timing detection model to produce snippets that begin at end-diastole, and involve contraction and dilatation for a complete cardiac cycle. A domain adversarial neural network was introduced to systematically address the appearance variability of echo videos in terms of noise, blur, transducer depth, contrast, etc. to improve the generalization of deep learning algorithms. In contrast to previous image-based cardiac disease detection architectures, video-based approaches integrate spatial and temporal information better with a more powerful 3D convolutional operator. RESULTS: Our proposed model achieved accuracy (ACC) of 92%, area under receiver operating characteristic (ROC) curve (AUC) of 0.90, sensitivity(SEN) of 97%, and specificity (SPE) of 84% with respect to subjects for hypertensive cardiomyopathy detection in the test data set, and outperformed the corresponding 3D CNN (vanilla I3D: ACC (0.90), AUC (0.89), SEN (0.94), and SPE (0.84)). On the whole, the video-based methods remarkably appeared superior to the image-based methods, while few evaluation metrics of image-based methods exhibited to be more compelling (sensitivity of 93% and negative predictive value of 100% for the image-based methods (ES/ED and random)). CONCLUSION: The results supported the possibility of using end-to-end video-based deep learning method for the automated diagnosis of hypertensive cardiomyopathy in the field of echocardiography to augment and assist clinicians. TRIAL REGISTRATION: Current Controlled Trials ChiCTR1900025325, Aug, 24, 2019. Retrospectively registered.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2023) conducted an observational in Hypertensive cardiomyopathy (n=297). Video-based deep learning method (3-D CNN) vs. Vanilla I3D 3D CNN was evaluated on Area under the ROC curve (AUC) for hypertensive cardiomyopathy detection (AUC 0.90, 95% CI 0.81-1.00, p=<0.001). A video-based deep learning model achieved an accuracy of 92% and an AUC of 0.90 for the automated detection of hypertensive cardiomyopathy from echocardiographic videos, outperforming the vanilla I3D model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: