Answers are grounded in this paper and cite their sources.
Significant research has been conducted to assess the amount of chlorides that results in corrosion initiation, C T , and propagation of the embedded reinforcing steel in concrete. However, the lack of a standard definition for corrosion initiation and the lack of a standard test and measurement criterion for determining corrosion initiation, all contribute to wide scatter in reported C T values in the literature. In this study, a hierarchical Bayesian approach is used to develop a predictive model for C T based on the reported C T values in the literature. The developed model accounts for the influence of cement type, supplementary cementitious materials, water-to-binder ratio, and the surface condition of the reinforcing steel on C T . The developed model can be used to streamline and standardize the process of selecting C T for service life modeling but to reduce the uncertainty in service-life predictions, it is essential to develop a standard test for determining C T .
No takes yet. Share an insight, caveat, or question.
Shakouri et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: