Why the study?
What are the determinants of discrepancies between different two-dimensional echocardiographic methods for assessing maximal left atrial volume?
What are the determinants of discrepancies between different two-dimensional echocardiographic methods for assessing maximal left atrial volume?
Left atrial geometry and body mass index are the main determinants of inconsistencies between 2D echocardiographic methods for measuring maximal left atrial volume, indicating these methods cannot be used interchangeably and the biplane area-length method should be preferred.
Geometry and BMI drive 2D LA volume discrepancies; leaves open whether standardized biplane protocols improve consistency in practice or trials.
AIMS: The determinants of discrepancies among two-dimensional echocardiographic (2D-E) methods for left atrial volume (LAV) assessment are poorly investigated. METHODS AND RESULTS: Maximal LAV was measured in 613 individuals (282 healthy subjects,180 athletes, and 151 hypertensives; age 45 ± 20 years, 62% male) using the ellipsoid model (LAVEllips), the area-length method (LAVAL), and the Simpson's rule (LAVSimps). On the basis of a mathematical model, two left atrial (LA) geometry indexes were tested as predictors of discrepancies between methods: the ratio between LA medial-lateral diameter (MLD) and LA anteroposterior diameter (APD); and the ratio between LA area in the four-chamber view and that of an ellipse with the same diameters [deviation from ellipse (DE)-coefficient]. Discrepancies among methods were consistently present in the overall population and across all study groups. MLD/APD and the DE-coefficient together predicted 76 and 68% of differences between biplane LAVAL and LAVEllips, and between biplane LAVSimps and LAVEllips, respectively. The DE-coefficient was the only determinant of LAVAL/LAVSimps difference (β = 0.167, P < 0.0001). Body mass index was the strongest predictor of discrepancies between single-plane and biplane approaches of LAVAL (β = 0.427, P < 0.0001) and LAVSimps (β = 0.424, P < 0.0001). In additional analyses, biplane LAVAL showed the best agreement with LAV obtained by three-dimensional echocardiography and the best reproducibility and repeatability. CONCLUSION: LA geometry is the main determinant of inconsistencies between 2D-E methods for measuring maximal LAV. Body mass index is the strongest determinant of differences between single-plane and biplane approaches. Different 2D-E methods cannot be used interchangeably for diagnosis and follow-up. The biplane area-length method should be preferred, particularly in overweight-obese subjects.
No takes yet. Share an insight, caveat, or question.
Ballo et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: