Key result
Two-dimensional transthoracic echocardiography underestimated left atrial volume compared to cardiac CT.
Why the study?
How accurate are two-dimensional echocardiographic and CT methods for measuring left atrial volume compared to a CT volumetric reference standard?
Observational (n=177)
How accurate are two-dimensional echocardiographic and CT methods for measuring left atrial volume compared to a CT volumetric reference standard?
While 2D echocardiography provides a reasonable assessment of left atrial volume, it significantly underestimates true volume compared to CT, with the biplane area-length method being the most accurate 2D estimate.
Answers are grounded in this paper and cite their sources.
Clinicians should interpret 2D echocardiographic left atrial volumes cautiously; Level 4 data leaves open validation against CT for outcomes.
BACKGROUND: Left atrial volume (LAVol) is an important predictor of cardiovascular outcomes. Different formulas are applied to calculate LAVol using two-dimensional transthoracic echocardiography (2DTTE) with variable reference values. The objective of the study was to evaluate the accuracy of methods to calculate LAVol by 2DTTE or cardiac computed tomography (CT). METHODS AND RESULTS: Overall 177 consecutive patients who underwent both a 2DTTE and retrospective electrocardiogram (ECG)-gated coronary CT angiography (CTA) within 15 days were included for this study. LA volume measurements were calculated by 2DTTE and 2DCT using the biplane area-length, biplane Simpson's, prolate-ellipsoid-1 and prolate-ellipsoid-2 methods. These results were compared with those measured by CT using a volumetric method. There was very good correlation between the CT and echocardiographic measures for LAVol, but significant underestimation of the echocardiographic methods when compared to the reference standard (33.5%, 39.1%, 48.1%, and 53.2% for the biplane area-length, biplane Simpson's, prolate-ellipsoid-1, and prolate-ellipsoid-2 methods, respectively). The biplane area-length method using 2DTTE had the closest volume estimation of all echocardiographic methods to the reference standard (67.6 ± 25.5 mL vs. 106 ± 35.5 mL, r = 0.712). Similarly, the biplane area-length method using CT most accurately predicted LAVol (103.3 ± 36.0 mL, r = 0.965). CONCLUSIONS: Compared to CT, 2DTTE provides reasonable assessment of LAVol, although all measurement methods underestimate LAVol. For both 2DTTE and CT, the biplane area-length method appears to provide the most accurate 2D estimate of LAVol.
No takes yet. Share an insight, caveat, or question.
Al‐Mohaissen et al. (2013) reported an observational. Two-dimensional transthoracic echocardiography (2DTTE) vs. Cardiac computed tomography (CT) was evaluated on Left atrial volume (LAVol) (r = 0.712). Two-dimensional transthoracic echocardiography underestimated left atrial volume compared to cardiac CT.
Synapse has enriched 10 related papers. Consider them for comparative context: