Why the study?
How do 2D and 3D measurement methods of left atrial volume using cardiac MDCT compare with each other and with echocardiography in patients screened for coronary artery disease?
How do 2D and 3D measurement methods of left atrial volume using cardiac MDCT compare with each other and with echocardiography in patients screened for coronary artery disease?
Cardiac MDCT correlates well with echocardiography for evaluating left atrial volume, but significantly overestimates end-systolic volume by 22%.
Answers are grounded in this paper and cite their sources.
MDCT LAESV overestimation precludes interchangeable use with echocardiography; leaves open validation of 3D-VTB thresholds in CAD screening.
OBJECTIVE: To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. MATERIALS AND METHODS: Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. RESULTS: The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3D-VTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. CONCLUSION: A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiography.
No takes yet. Share an insight, caveat, or question.
Gweon et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: