Why the study?
Fluoroscopy remains widely used during ablation procedures despite non-fluoroscopic visualization, prompting the evaluation of the safety and efficacy of a new ultra-low dose radiation protocol in a large patient cohort.
Does an ultra-low dose radiation protocol maintain safety and efficacy while reducing radiation exposure in patients undergoing radiofrequency ablation?
Does an ultra-low dose radiation protocol maintain safety and efficacy while reducing radiation exposure in patients undergoing radiofrequency ablation?
An ultra-low dose radiation protocol for electrophysiology procedures significantly reduces radiation exposure without compromising procedural success or safety.
Answers are grounded in this paper and cite their sources.
Ultra-low dose protocols may reduce radiation in ablations; leaves open randomized confirmation of safety and efficacy.
Introduction Despite the development of non‐fluoroscopic catheter visualization options, fluoroscopy is still used in most ablation procedures. The aim of this multicenter study was to evaluate the safety and efficacy of a new ultra‐low dose radiation protocol for EP procedures in a large number of patients. Methods and results A total of 3462 consecutive patients (male 1926 (55.6%), age 64.4 ± 14.0 years, BMI 26.65 ± 4.70) undergoing radiofrequency ablation (left atrial (n = 2316 [66.9%], right atrial (n = 675 [19.5%], or ventricular (n = 471 [13.6%]) in three German centers were included in the analysis. Procedures were performed using a new ultra‐low dose protocol operating at 8nGy for fluoroscopy and 36nGy for cine‐loops. Additionally a very low framerate (2‐3FPS) was used. Using the new protocol very low Air kerma‐area product (KAP) values were achieved for left atrial ablations (104.25 ± 84.22 μGym 2 ), right atrial ablations (70.98 ± 94.79 μGym 2 ) and ablations for ventricular tachycardias or PVCs (78.62 ± 66.59 μGym 2 ). Acute procedural success was achieved in 3289/3388 (97.1%) while the rate of major complications was very low compared to previously published studies not using low dose settings (n = 20, 0.6%). Conclusion The ultra‐low dose, low framerate protocol leads to very low radiation doses for all EP procedures while neither procedural time, fluoroscopy time nor success or complication rates were compromised. When compared to current real‐world Air KAP data the new ultra‐low dose fluoroscopy protocol reduces radiation exposure by more than 90%.
No takes yet. Share an insight, caveat, or question.
Attanasio et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: