Why the study?
The Ross procedure relies on preserving pulmonary valve anatomy, but limited data exist regarding normal pulmonary valve geometry.
Do pulmonary root and cusp dimensions differ from aortic root and cusp dimensions in normal adults on computed tomography?
Do pulmonary root and cusp dimensions differ from aortic root and cusp dimensions in normal adults on computed tomography?
Answers are grounded in this paper and cite their sources.
Computed tomography reveals that the pulmonary root has a different shape and lower cusp effective height than the aortic root, suggesting that during the Ross procedure, the autograft should be stabilized to normal aortic root dimensions.
OBJECTIVES: The Ross procedure is currently receiving renewed interest. Its function and durability depend on preservation of pulmonary valve anatomy; limited data exist on normal pulmonary valve geometry. The objective was to compare aortic and pulmonary root and cusp dimensions in adults with normal tricuspid aortic and pulmonary valves. METHODS: We reviewed 507 coronary computed tomography studies, selecting those with adequate visibility of both pulmonary and aortic roots for further analysis. Diastolic aortic and pulmonary root and cusp dimensions were measured. Root dimensions at different phases of the cardiac cycle were measured in 3 patients. RESULTS: We analysed studies of 50 patients with the mean age of 54 years [standard deviation (SD): 16]. In end-diastole, pulmonary root had a smaller sinutubular to basal ring ratio than the aortic root [0.82 (SD: 0.09) vs 1.14 (SD: 0.12), P < 0.001]. Aortic and pulmonary cusps had similar dimensions; however, pulmonary cusp effective height was lower [5.9 mm (SD: 1.6) vs 8.4 mm (SD: 1.2), P < 0.001]. Pulmonary basal ring perimeter was largest at end-diastole and smallest at end-systole, with the relative difference of 23.5% (SD: 2.7). CONCLUSIONS: The pulmonary root has a similar cusp size compared to the aortic root, but a different shape, resulting in a lower pulmonary cusp effective height. The perimeter of the pulmonary basal ring changes during the cardiac cycle. These findings suggest that stabilizing the autograft to normal aortic, rather than pulmonary, root dimensions should result in normal autograft cusp configuration. Computed tomography angiography could become a tool for personalized planning of the Ross procedure.
No takes yet. Share an insight, caveat, or question.
Jelenc et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: