January 1, 2012Journal of Cardiovascular Magnetic ResonanceOpen Access

MultiContrast Delayed Enhancement (MCODE) improves detection of subendocardial myocardial infarction by late gadolinium enhancement cardiovascular magnetic resonance: a clinical validation study

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does MCODE improve the detection of myocardial infarction compared to standard LGE imaging in patients referred for CMR?

Population

73 patients referred for cardiovascular magnetic resonance including a late gadolinium enhancement study. 46…

Comparison

MultiContrast Delayed Enhancement CMR imaging vs Standard phase sensitive inversion recovery LGE…

Design

Cross-sectional, Images at each of multiple time points were read on separate…

Authors

WBW. Patricia BandettiniPKPeter KellmanCMChristine Mancini

Discussion

Loading...

Member takes

Overview

May enhance subendocardial MI detection on CMR; leaves open its role pending prospective validation.

Structured PICO

Does MCODE improve the detection of myocardial infarction compared to standard LGE imaging in patients referred for CMR?

P
Population
73 patients referred for cardiovascular magnetic resonance (CMR) including a late gadolinium enhancement (LGE) study. 46 patients had a final diagnosis of MI (30 subendocardial and 16 transmural).
I
Intervention
MultiContrast Delayed Enhancement (MCODE) CMR imaging
C
Comparator
Standard phase sensitive inversion recovery (PSIR) LGE imaging
O
Outcome
Detection of myocardial infarction (presence, transmural vs subendocardial, and extent on a sector-by-sector basis)surrogate

MCODE improves the detection of subendocardial myocardial infarction compared to standard LGE imaging by providing simultaneous T1 and T2-weighted images to better differentiate blood pool from enhanced myocardium.

Cite This Study

Bandettini et al. (2012) studied this question.

synapsesocial.com/papers/6a828cae92c19701ea21dc1bhttps://doi.org/10.1186/1532-429x-14-83
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Multicontrast delayed enhancement provides improved contrast between myocardial infarction and blood pool2005 · 51 citations
  2. 2Performance of Delayed-Enhancement Magnetic Resonance Imaging With Gadoversetamide Contrast for the Detection and Assessment of Myocardial Infarction2008 · 279 citations
  3. 3Impact of Unrecognized Myocardial Scar Detected by Cardiac Magnetic Resonance Imaging on Event-Free Survival in Patients Presenting With Signs or Symptoms of Coronary Artery Disease2006 · 756 citations
  4. 4The Use of Contrast-Enhanced Magnetic Resonance Imaging to Identify Reversible Myocardial Dysfunction2000 · 3,311 citations
  5. 5Myocardial Infarct: Depiction with Contrast-enhanced MR Imaging—Comparison of Gadopentetate and Gadobenate2005 · 44 citations