Answers are grounded in this paper and cite their sources.
We investigated the test–retest reliability of the protocol for determining the peak backward running velocity (Vpeak_BR) and the heart rate (HR) and rating of perceived exertion (RPE) at maximal and submaximal intensities during this protocol. The Vpeak_BR showed high reliability, presenting an intraclass correlation coefficient (ICC) and coefficient of variation (CV) of 0.91% and 4.5%; Vpeak_BR showed the lowest bias and limits of agreement between test-retest. In addition, there was no statistical test–retest difference for Vpeak_BR (p = .10). The HRpeak did not demonstrate a statistical difference between test-retest and showed moderate reliability, without statistical difference between test–retest (ICC = 0.83; CV = 2.8%;); for the RPEpeak, no statistical difference was demonstrated between test–retest and questionable reliability (ICC = 0.71; CV = 8.2%). Significant differences in HR and RPE were observed at submaximal intensities between test-retest in the Vpeak_BR protocol. It was concluded that the protocol for determining Vpeak_BR is reliable, suggesting that it can be used to prescribe and monitor BR training intensities.
No takes yet. Share an insight, caveat, or question.
Silveira et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: