Key result
Prolonged door-to-balloon time of 90 minutes or greater was an independent predictor for left ventricular diastolic dysfunction (OR 1.82), particularly in patients aged 65 years or older.
Why the study?
Does a door-to-balloon time of <90 minutes prevent left ventricular diastolic dysfunction in STEMI patients undergoing primary PCI?
Observational (n=340)
No
Does a door-to-balloon time of <90 minutes prevent left ventricular diastolic dysfunction in STEMI patients undergoing primary PCI?
Prolonged door-to-balloon time (≥90 min) in STEMI patients undergoing primary PCI is associated with an increased risk of early left ventricular diastolic dysfunction, particularly in older patients.
Answers are grounded in this paper and cite their sources.
May support minimizing door-to-balloon time to mitigate LV diastolic dysfunction in elderly STEMI patients; leaves open need for randomized confirmation.
BACKGROUND: Emerging evidence indicates that diastolic left ventricular (LV) function is a powerful outcome predictor after acute ST-elevation myocardial infarction (STEMI). We hypothesized that shorter door-to-balloon (D2B) times with early restoration of coronary perfusion may preserve diastolic LV function in STEMI patients undergoing primary percutaneous coronary intervention (PPCI). METHODS: This study enrolled 340 consecutive STEMI patients who underwent PPCI with D2B times of < 90 min in 232 patients and D2B times ≥ 90 min in 108 patients, who all received subsequent echocardiographic examination within 48 hours of hospitalization. RESULTS: Although the LV ejection fraction was similar (50.92% vs. 51.66%, p = 0.573), the proportion of E/E' ratio > 15 was greater in patients with D2B times ≥ 90 min compared to those with D2B times < 90 min (44.4% vs. 30.6%, p = 0.013). Logistic regression analysis revealed that D2B time ≥ 90 min [odds ratio (OR): 1.82, 95% confidence interval (Cl): 1.04-3.17, p = 0.035] was an independent predictor for LV diastolic dysfunction. The effect was more prominent in patients ≥ 65 years of age (OR: 2.77, 95% CI: 1.09-7.00, p = 0.032), in whom the fraction of LV diastolic dysfunction increased proportionally with prolonged D2B times. CONCLUSIONS: Prolonged D2B time of greater than 90 min predicted LV diastolic dysfunction, particularly in aged subjects. D2B times shortening is important to preserve diastolic heart function after PPCI.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2015) conducted an observational in Acute ST-Elevation Myocardial Infarction (STEMI) (n=340). Prolonged door-to-balloon (D2B) time ≥ 90 min vs. Door-to-balloon (D2B) time < 90 min was evaluated on Left ventricular diastolic dysfunction (E/E' ratio > 15) (OR 1.82, 95% CI 1.04-3.17, p=0.035). Prolonged door-to-balloon time of 90 minutes or greater was an independent predictor for left ventricular diastolic dysfunction (OR 1.82), particularly in patients aged 65 years or older.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: