Key result
Bicuspid aortic valve aneurysm tissue exhibited a >20% greater elastic modulus compared to degenerative aneurysm and control tissue, indicating a greater loss of aortic wall compliance.
Why the study?
To explore the micromechanical, biochemical, and microstructural differences between bicuspid aortic valve aneurysm and tricuspid aortic valve idiopathic degenerative aneurysm compared with normal aorta.
Observational (n=39)
Bicuspid aortic valve aneurysms exhibit a distinct pattern of matrix degradation characterized by greater loss of aortic wall compliance and elastin compaction within the media compared to degenerative aneurysms.
Supports biomechanical distinction in bicuspid aortic valve aneurysms; leaves open whether this alters thresholds pending prospective data.
OBJECTIVE: To explore the micromechanical, biochemical, and microstructural differences between bicuspid aortic valve aneurysm (BAV-A) and tricuspid aortic valve idiopathic degenerative aneurysm (DA), compared with normal aorta. METHODS: Aortic tissue was obtained from patients undergoing aneurysmal repair surgery (BAV-A; n = 15 and DA; n = 15). Control tissue was obtained from aortic punch biopsies during coronary artery bypass graft surgery (n = 9). Nanoindentation was used to determine the elastic modulus on the medial layer. Glycosaminoglycan, collagen, and elastin levels were measured using biochemical assays. Verhoeff Van Gieson-stained cross-sections were imaged for elastin microstructural quantification. RESULTS: The elastic modulus was more than 20% greater for BAV-A relative to control and DA (signifying a loss of compliance). No significance difference between control and DA were observed. Collagen levels for BAV-A (36.9 ± 7.4 μg/mg) and DA (49.9 ± 10.9 μg/mg) were greater compared with the control (30.2 ± 13.1 μg/mg). Glycosaminoglycan and elastin levels were not significant between the groups. Elastin segments were uniform throughout the control. Aneurysmal tissues had less elastin segments close to the intima and adventitia layers. Both BAV-A and DA had elastin segments compacted in the media; however, elastin segments were highly fragmented in DA. CONCLUSIONS: BAV-A has a greater loss of aortic wall compliance relative to DA and the control. Although elastin levels were equal for all groups, spatial distribution of elastin provided a unique profile of matrix degradation for BAV-A. Elastin compaction within the media of BAV-A may have resulted from the altered hemodynamic pressure against the wall, which could explain for the stiffness of the tissue.
No takes yet. Share an insight, caveat, or question.
Chim et al. (2019) conducted an observational in Bicuspid aortic valve aneurysm (n=39). Bicuspid aortic valve aneurysm (BAV-A) vs. Tricuspid aortic valve idiopathic degenerative aneurysm (DA) and normal aorta was evaluated on Elastic modulus and biochemical matrix levels (collagen, elastin, glycosaminoglycan). Bicuspid aortic valve aneurysm tissue exhibited a >20% greater elastic modulus compared to degenerative aneurysm and control tissue, indicating a greater loss of aortic wall compliance.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: