Key result
Screen-detected incident atrial fibrillation was associated with increased mortality (HR 2.21; 95% CI 1.09-4.47), with no significant difference in risk compared to clinically detected AF (P=0.447).
Why the study?
It was unknown whether screen-detected atrial fibrillation carries cardiovascular risks similar to clinically detected atrial fibrillation.
Does screen-detected atrial fibrillation carry similar risks for mortality, incident heart failure, and vascular events compared to clinically detected atrial fibrillation in a community-based cohort?
Cohort (n=8,265)
Does screen-detected atrial fibrillation carry similar risks for mortality, incident heart failure, and vascular events compared to clinically detected atrial fibrillation in a community-based cohort?
Hazard Ratio: 2.21 (95% CI 1.09–4.47)
p-value: p=0.447 for difference
Screen-detected atrial fibrillation carries a similarly increased risk for all-cause mortality and incident heart failure as clinically detected atrial fibrillation, highlighting that it is not a benign condition.
Screen-detected AF warrants similar clinical attention as clinically detected AF; leaves open whether screening improves outcomes in community cohorts.
AIMS: It is unknown whether screen-detected atrial fibrillation (AF) carries cardiovascular risks similar to clinically detected AF. We aimed to compare clinical outcomes between individuals with screen-detected and clinically detected incident AF. METHODS: We studied 8265 participants (age 49 ± 13 years, 50% women) without prevalent AF from the community-based Prevention of Renal and Vascular End-stage Disease (PREVEND) study. By design of the PREVEND study, 70% of participants had a urinary albumin concentration >10 mg/L. Participants underwent 12-lead ECG screening at baseline and every 3 years. AF was considered screen-detected when first diagnosed during a study visit and clinically detected when first diagnosed during a hospital visit. We analysed data from the baseline visit (1997-1998) up to the third follow-up visit (2008). We used Cox regression with screen-detected and clinically detected AF as time-varying covariates to study the association of screen-detected and clinically detected AF with all-cause mortality, incident heart failure (HF) and vascular events. RESULTS: During a follow-up of 9.8 ± 2.3 years, 265 participants (3.2%) developed incident AF, of whom 60 (23%) had screen-detected AF. The majority of baseline characteristics were comparable between individuals with screen-detected and clinically detected AF. Unadjusted, both screen-detected and clinically detected AF were strongly associated with mortality, incident HF, and vascular events. After multivariable adjustment, screen-detected and clinically detected AF remained significantly associated with mortality (HR 2.21 (95% CI 1.09 to 4.47) vs 2.95 (2.18 to 4.00), p for difference=0.447) and incident HF (4.90 (2.28 to 10.57) vs 3.98 (2.49 to 6.34), p for difference=0.635). After adjustment, screen-detected AF was not significantly associated with vascular events, whereas clinically detected AF was (1.12 (0.46 to 2.71) vs 1.92 (1.21 to 3.06), p for difference=0.283). CONCLUSION: Screen-detected incident AF was associated with an increased risk of adverse outcomes, especially all-cause mortality and incident HF. The risk of outcomes was not significantly different between screen-detected AF and clinically detected AF.
No takes yet. Share an insight, caveat, or question.
Zwartkruis et al. (2021) conducted a cohort in Incident atrial fibrillation (n=8,265). Screen-detected atrial fibrillation vs. Clinically detected atrial fibrillation was evaluated on All-cause mortality (HR 2.21, 95% CI 1.09 to 4.47, p=0.447 for difference). Screen-detected incident atrial fibrillation was associated with increased mortality (HR 2.21; 95% CI 1.09-4.47), with no significant difference in risk compared to clinically detected AF (P=0.447).