What is the rate of defibrillation testing during ICD implantation and its associated complications in real-world practice?
What is the rate of defibrillation testing during ICD implantation and its associated complications in real-world practice?
In real-world practice, a substantial number of ICDs are implanted without defibrillation testing, which itself carries a small but non-negligible risk of life-threatening complications (0.4%).
Answers are grounded in this paper and cite their sources.
Omitting DT in 30% of ICD implants without clear rationale warrants caution; leaves open whether routine testing improves net clinical benefit.
AIMS: Despite an effective defibrillation testing (DT) is considered mandatory to be consistent with the rules of good clinical practice, some physicians are concerned about the risk of complications related to the induction test, and in real world clinical practice, several implant procedures are performed without any induction test. We conducted a systematic nation-wide retrospective survey in order to determine the DT rate and its complications. METHODS AND RESULTS: An ad hoc questionnaire was sent to all 343 Italian implanting centres and the data from the 229 (67%) centres that answered were analysed. During the year 2005, a total of 7857 patients underwent a first implantation of cardioverter defibrillator (ICD), 38% of which with cardiac resynchronization therapy (CRT). Of these, 2356 (30%) were implanted without any induction test. In 35 (15%) centres, the induction test was performed in < 25% of the patients, whereas in 136 (59%) centres, it was performed in > 75% of the patients. At multivariable analysis, performed in a subset of 1206 patients from 107 centres, CRT device (OR = 1.82) and primary prevention (OR = 1.47) were independent predictors of the decision to not perform DT. However, altogether, the clinical variables accounted only for 35% of the total variance, whereas the remaining 65% was probably unrelated to clinical factors. There was a total of 22 (0.4%) life-threatening complications as a consequence of the induction test: 4 deaths (0.07%), 8 cardiopulmonary arrests requiring resuscitation manoeuvres (0.15%), 6 cardiogenic shocks (0.11%), 3 strokes (0.05%), and 1 pulmonary embolism (0.02%). CONCLUSION: In real world practice, DT is not performed in a substantial number of patients, most of these in the absence of legitimate reasons. The clinical impact of DT vs. no DT remains unclear until the not negligible complication rate is compared against the long-term potential benefit.
No takes yet. Share an insight, caveat, or question.
Brignole et al. (2007) studied this question.