Why the study?
Does a program encouraging low flow anaesthesia with feedback reduce isoflurane consumption?
Does a program encouraging low flow anaesthesia with feedback reduce isoflurane consumption?
A feedback program encouraging low flow anaesthesia significantly reduced isoflurane consumption and generated substantial cost savings.
Answers are grounded in this paper and cite their sources.
Feedback-driven low-flow anaesthesia was associated with reduced isoflurane use and costs; hypothesis-generating for wider adoption.
A three-month audit of isoflurane consumption at Palmerston North Hospital in 1994 showed an averaged vapour flow rate of approx 85 ml per minute of anaesthesia, equivalent to 1.4% isoflurane at six litres per minute. After purchasing volatile agent analysers, a program encouraging low flow anaesthesia and providing a report of the previous month's consumption rate was started in July 1996. The isoflurane averaged vapour flow rate was tracked over the following twenty-month period and fell by a sustained 65% to range around 30 +/- 5 ml/min, producing savings of approximately NZ$104,000 over this period.
No takes yet. Share an insight, caveat, or question.
Andrew J. McKenzie (1998) studied this question.