As part of the Prospective Evaluation of Radial Keratotomy (PERK) study, we examined the relationship between post-operative refractive error and visual acuity without correction. We included 394 eyes (one eye per patient) with refractive errors ranging from -3.00 to +3.00 diopters one year after radial keratotomy. Within each 1-D range of the spherical equivalent of the refractive error, the visual acuity spanned five to ten Snellen lines. For visual acuities of 20/16 to 20/50, the refractive error spanned 3 to 5 D. Additionally, operated eyes had a better average uncorrected visual acuity than unoperated eyes with a similar refractive error. Within the narrow range of refraction between -2.00 and -2.50 D, the mean uncorrected visual acuity was 20/125 for 56 unoperated eyes and 20/63 for 29 operated eyes, a difference of three Snellen lines.
No takes yet. Share an insight, caveat, or question.
Santos et al. (1987) studied this question.