Why the study?
Does serial monitoring with duplex scanning and Doppler-derived blood pressure measurements predict restenosis and clinical failure in patients who underwent percutaneous transluminal angioplasty?
Does serial monitoring with duplex scanning and Doppler-derived blood pressure measurements predict restenosis and clinical failure in patients who underwent percutaneous transluminal angioplasty?
Duplex scanning within 1 week of lower extremity angioplasty can identify residual stenosis that strongly predicts long-term clinical success or failure.
Supports early duplex for risk stratification after lower extremity PTA; leaves open whether findings should guide intervention.
Duplex scanning and Doppler-derived blood pressure measurements were used to serially monitor lower limb hemodynamics in 73 patients who underwent percutaneous transluminal angioplasty. Ninety percutaneous transluminal angioplasty sites judged technically satisfactory by arteriography were evaluated. Significant hemodynamic improvement was seen in 81 (90%) of the 90 limbs, although both hemodynamic and clinical improvement were achieved in only 77 (86%) limbs. Duplex scanning within 1 week of successful angioplasty identified moderate (20% to 49% diameter reduction) or severe (greater than 50% diameter reduction) residual stenosis in 49 (63%) of 77 balloon-dilated arterial segments. The presence of a greater than 50% diameter reduction residual stenosis predicted further restenosis and late clinical failure (11% success rate at 1 year). When the degree of residual stenosis at the percutaneous transluminal angioplasty site was less than 50% diameter reduction by duplex scanning, the procedure was durable (80% success rate at 2 years), even in patients with critical ischemia, poor runoff, or diabetes mellitus.
No takes yet. Share an insight, caveat, or question.
Edward V. Kinney (1991) studied this question.