Answers are grounded in this paper and cite their sources.
The 7-day physical activity recall (PAR) is one of the most commonly used activity assessments in the exercise science field. The purpose of this study was to evaluate the convergent validity of several PAR-scoring algorithms against a temporally matched measure from an accelerometry-based activity monitor. The participants (n = 24) in the study wore a Tritrac monitor for a period of 8 days and completed a structured PAR interview to recall their activity over the same time frame. The raw energy expenditure (EE) estimate from the Tritrac was found to underpredict the magnitude of the PAR estimate, but the correlation between measures was high (r = .72). The correspondence in EE was better, and the correlation between measures were higher (r = .84 to r = .95) when alternative PAR and Tritrac scoring algorithms were tested. There was no evidence of memory decay, as the correlation remained consistent across all 7 days of recall. The results support the continued use of the PAR for exercise science and epidemiological research and suggest that an alternative PAR scoring system that incorporates sitting time as rest may improve the validity of the assessment.
No takes yet. Share an insight, caveat, or question.
Welk et al. (2001) studied this question.