Answers are grounded in this paper and cite their sources.
Ethical considerations and ACC guidelines dictate that ICDs should not be implanted in patients with a life expectancy of less than 1 year, highlighting the importance of accurate prognostic assessment prior to implantation.
“Why do you people put defibrillators in if we have to deactivate them in a couple of months?” There was no mistaking the accusation of impropriety on the part of my palliative care colleague. My reply that defibrillators were not indicated in patients with a limited life expectancy according to the guidelines of the American College of Cardiology (ACC) and Heart Rhythm Society met with a bit of derision. Clearly, in this physician's experience, electrophysiologists were anxious to implant defibrillators in patients who met criteria based on ejection fraction, but ignored potentially serious and life-threatening coexisting medical conditions. Since the two of us were participants in an Ethics Consultation course, it was proper to consider whether my colleague's concerns reflected a true ethical dilemma. The ACC Guidelines for device-based therapy1 state that “Recommendations for consideration of implantable cardioverter defibrillator (ICD) therapy, particularly those for primary prevention, apply only to patients who are receiving optimal medical therapy and have a reasonable expectation of survival with a good functional status for more than 1 year.” The guidelines add that even if the patient meets other criteria for implantation, they should not have an ICD implanted if there is not a reasonable life expectancy of over 1 year. Thus, one wonders how these patients were accepted for ICD implantation if, several months later, a palliative care physician was asked to deactivate the device. To analyze this further, a literature search was conducted to see if there were cases to be used as models. Much has been written about deactivating automatic defibrillators at the end of life. As early as 1994, when defibrillators were only available for secondary prevention, Quill2 reported the case of a patient with frequent shocks for ventricular tachycardia who requested device deactivation. Due to differing values of the physician and patient, and confusion about the patient's right to refuse therapy, device deactivation took nearly a year to accomplish, during which time the patient experienced shocks every 4–6 weeks. A case report by Nambisan and Chao3 described a woman who had a secondary prevention ICD implanted 5 years earlier and developed advanced lung cancer. Despite a do-not-resuscitate order, her end-of-life care was complicated by multiple shocks for atrial fibrillation until the device could be deactivated. In these cases, the ICDs were implanted years before the diagnosis of malignancy, after a bout of ventricular tachycardia or cardiac arrest. The contemporary population, however, is much more mixed, with the vast majority receiving these devices for primary prevention of sudden cardiac death. The ethical issues surrounding benefit of these devices become less clear if there are confounding medical problems. There is limited information on the subset of patients my colleague was concerned about: those who had devices implanted shortly before a terminal illness required deactivation. Kobza and Erne4 reviewed 272 patients with ICD implantation over a 13-year period, and found 36 deaths, of which eight patients had malignant tumors. Five of the eight had previously experienced symptomatic or induced ventricular tachyarrhythmias. In these eight cases, three had the malignancy at the time of ICD implantation, and one of the remaining five was diagnosed with a malignancy within a few months of implantation. In the former cases, the oncologist had estimated a greater than 5-year survival rate. Five of the eight patients died of their malignancy within 1 year of diagnosis. The remaining three patients had uroepithelial or prostate cancer, and had extended life expectancies. Despite care on the part of the electrophysiologists prior to device implantation, the potential for survival in the patients who died was overestimated by the oncologists. This represents a very small sample, but the ethicist must question how often this situation actually arises. Unfortunately, much of the ethical debate surrounding ICDs has focused on deactivation once the patient's condition becomes terminal. Deciding whether to implant, however, should involve the same ethical reflection. According to the model of Beauchamp and Childress,5 physicians have moral obligations to respect patient autonomy, act to provide beneficial treatment (beneficence), avoid harm (nonmaleficence), and act justly (justice). Acceptance that patients have the autonomous right to refuse therapy has improved over the past decade, and the legal issues involving patients’ rights have been clarified. Berger6 discussed the ethical implantation of deactivating the ICD in the context of a patient with pneumonia and dementia. He stated that although ICDs provide the same remedy as external defibrillators, ICDs should not be considered as resuscitation. Since cardiac arrest is a continuum involving progressive physiologic instability, the therapy provided by an ICD is merely a component of this process. Thus, the use of a defibrillator may be appropriate in some cases, and not in others, depending on the patient's desires about their care. This approach was echoed by England et al.7 who proposed considering ICDs as “integral devices” or as a middle ground between medical device (under control of the physician) or part of the body (under control of the patient) and that the patient has the stronger autonomy to choose deactivation of the device when it no longer meets treatment goals. England further posits that although consent involves specifics of ICD maintenance, it may be inappropriate to discuss the prospect of disabling the device in the future. Beneficence and nonmaleficence demand that the potential benefit of the device, even in the short term, is weighed against the harm of inappropriate therapy in a patient whose illness advances to a point where the ICD no longer helps meet a therapeutic goal. Social justice obligates the physician to consider whether the implantation of a device is appropriate from a societal standpoint: the use of an expensive therapy in an individual where it will convey a questionable benefit. So how should I have answered my colleague? Certainly, the physicians who knowingly inserted a device in a patient with a limited life expectancy may have used flawed judgment. They might argue that the patient met the criteria to have a device implanted, and that the long-term prognosis of the other illnesses was unknown at the time. They may be concerned that failure to offer such therapy would be a breach of their professional duties to that patient. The AMA Code of Ethics8 makes it clear that physicians do not have an obligation to offer therapy that will be medically futile. In the end, many patients who have multiple medical problems, including cancer, do not die of cardiac arrest from ventricular tachycardia or fibrillation, but from multisystem failure that cannot be prevented with an ICD. In these cases, it is a breach of ethics to offer a therapy that is not of benefit to the patient, and may be harmful, subjecting them to inappropriate shocks. Given the issues raised in the paper by Kobza,4 it might be appropriate to clarify whether or not the patients do have a malignancy at the time of implant, so that appropriate considerations might be made about the actual benefits of ICD therapy in the context of all of the patient's medical issues.
No takes yet. Share an insight, caveat, or question.
Lou-Anne M. Beauregard (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: