Why the study?
Does echocardiographic pulmonary acceleration time (AT) accurately estimate pulmonary pressures and vascular resistance in patients evaluated for possible pulmonary hypertension?
Does echocardiographic pulmonary acceleration time (AT) accurately estimate pulmonary pressures and vascular resistance in patients evaluated for possible pulmonary hypertension?
Echocardiographic acceleration time from the RVOT <100 ms is a reliable indicator of pulmonary hypertension, offering a useful non-invasive diagnostic alternative when tricuspid regurgitation signals are inadequate.
AT <100 ms may aid SPAP estimation when TR signals are inadequate; leaves open prospective validation before changing pulmonary hypertension diagnostic pathways.
BACKGROUND: During ultrasound examination, tricuspid regurgitation may be absent or gives a signal that is not reliable for the estimation of systolic pulmonary pressure. The aim of this study was to evaluate the usefulness of acceleration time (AT) from the right ventricular outflow tract (RVOT) as an estimation of the trans-tricuspid valve gradient (TTVG) and to investigate the correlation between estimated and invasive pulmonary vascular resistance (PVR). METHODS: The AT was correlated to the TTVG measured with routine standard echocardiography in 121 patients. In a subgroup of 29 patients, systolic pulmonary pressure (SPAP) and mean pulmonary arterial pressure (MPAP) were obtained from recent right heart catheterization (RHC). RESULTS: We found no significant correlation between the estimation of right atrial pressure (RAP) by echocardiography and the RAP obtained by RHC. Estimated SPAP (TTGV + RAP mean from RHC) showed a good linear relation to invasively measured SPAP. TTVG and AT showed a non-linear relation, similar to SPAP and MPAP measured by catheterization and AT. For detection of SPAP above 38 mmHg a cut-off for AT of 100 ms resulted in a sensitivity of 89% and a specificity of 84%. For detection of MPAP above 25 mmHg a cut-off for AT of 100 ms resulted in similar sensitivity and specificity. Invasive PVR and the ratio of TTVG and the time velocity integral of the RVOT (TVI (RVOT) ) had a strong linear relation. CONCLUSIONS: Our study confirms that AT appears to be useful for the evaluation of pulmonary hypertension. In high risk patients, an AT of less than 100 ms indicates a high probability of pulmonary hypertension. Furthermore, PVR estimation by ultrasound seems preferably be done by using the ratio of TTVG and TVI RVOT.
No takes yet. Share an insight, caveat, or question.
Granstam et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: