Key result
Transcatheter implantation of an injectable tissue-engineered pulmonary heart valve was successfully performed in 6 of 7 pigs without tissue distortion from the delivery system.
Transcatheter implantation of an injectable tissue-engineered pulmonary heart valve is feasible and does not cause delivery-related tissue distortion in an acute pig model.
Answers are grounded in this paper and cite their sources.
Supports acute feasibility in pigs; leaves open human translation and durability testing.
BACKROUND: Transcatheter pulmonary valve replacement is currently performed in clinical trials, however limited by the use of glutaraldehyde treated bioprostheses. This feasibility study was performed to evaluate delivery-related tissue distortion during implantation of a tissue engineered (TE) heart valves. MATERIAL AND METHOD: The injectable TE heart valve was mounted on a self-expanding nitinol stent (n=7) and delivered into the pulmonary position of seven pigs, (weight 26 to 31 kg), performing a sternotomy or limited lateral thoracotomy. Prior to implantation, the injectable TE heart valve was crimped and inserted into an applicator. Positioning of the implants was guided by fluoroscopy and after carefully deployment angiographic examination was performed to evaluate the correct delivered position. Hemodynamic measurements were performed by epicardial echocardiography. Finally, the animals were sacrificed and the injectable TE heart valves were inspected by gross examination and histological examination. RESULTS: Orthotopic delivery of the injectable TE heart valves were all successful performed, expect in one were the valve migrated due to a discrepancy of pulmonary and injectable TE valve size. Angiographic evaluation (n=6) showed normal valve function, supported by epicardial echocardiography in which no increase flow velocity was measured, neither trans- nor paravalvular regurgitation. Histological evaluation demonstrated absence of tissue damage due to the delivery process. CONCLUSIONS: Transcatheter implantation of an injectable TE heart valve seems to be possible without tissue distortion due to the delivery system.
No takes yet. Share an insight, caveat, or question.
Schlegel et al. (2015) studied Pulmonary valve replacement (animal model) (n=7). Injectable tissue-engineered pulmonary heart valve was evaluated on Delivery success and tissue distortion. Transcatheter implantation of an injectable tissue-engineered pulmonary heart valve was successfully performed in 6 of 7 pigs without tissue distortion from the delivery system.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: