Key result
A combined tissue Doppler index of an inferior annular systolic velocity > 7.5 cm/s and an anterior mitral annular early diastolic velocity > 8 cm/s predicted preserved global left ventricular function with 69% sensitivity, 94% specificity, and 86% overall diagnostic accuracy.
Why the study?
Does tissue Doppler echocardiography of mitral annulus corners predict preserved global left ventricular function in patients with acute anterior myocardial infarction?
Cross-Sectional (n=50)
Single-blind
No
Does tissue Doppler echocardiography of mitral annulus corners predict preserved global left ventricular function in patients with acute anterior myocardial infarction?
Tissue Doppler echocardiography parameters of the inferior and anterior mitral annulus corners can accurately predict preserved global left ventricular function in the early phase of an acute anterior myocardial infarction.
May support mitral annular tissue Doppler to assess LV function post-anterior MI; leaves open prospective validation before practice change.
The degree of left ventricular (LV) dysfunction determines the outcome of patients suffering an acute anterior myocardial infarction (AAMI). Many recent studies have utilized tissue Doppler echocardiography (TDE) parameters in the assessment of LV function. We sought to investigate whether some variables easily obtained from TDE profiles of mitral annulus corners would predict a relatively preserved LV global function traditionally assessed with ejection fraction (EF) and deceleration time (DT), within the acute phase of AAMI. Included were 50 consecutive patients with a first AAMI. Standard echocardiography and TDE of mitral annulus were performed within 36 hours of admission. Pulsed wave sample volumes were set at the septal, lateral, anterior, and inferior corners of the mitral annulus. Preserved LV function was defined as an EF > 40% together with a DT > or = 140 ms and < 220 ms. An inferior annular systolic velocity of > 7.5 cm/s predicts preserved global left ventricular function with a sensitivity of 81% and specificity of 71%. An anterior mitral annular early diastolic velocity of > 8cm/s had a sensitivity of 69% and specificity of 85%. When these two velocities both exceed the limits above, such a combined index yielded a sensitivity of 69%, specificity of 94%, and an overall diagnostic accuracy of 86% for the estimation of preserved LV global function. The parameters derived from TDE profiles of inferior and anterior mitral annulus comers provide valuable information to predict preserved global left ventricular function during the early period of AAMI.
No takes yet. Share an insight, caveat, or question.
Akdemir et al. (2003) conducted a cross-sectional in Acute anterior myocardial infarction (n=50). Tissue Doppler echocardiography (TDE) parameters vs. Standard echocardiography (EF and DT) was evaluated on Prediction of preserved global left ventricular function (EF > 40% and DT ≥ 140 ms and < 220 ms) (Sensitivity 69%, Specificity 94%). A combined tissue Doppler index of an inferior annular systolic velocity > 7.5 cm/s and an anterior mitral annular early diastolic velocity > 8 cm/s predicted preserved global left ventricular function with 69% sensitivity, 94% specificity, and 86% overall diagnostic accuracy.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from Japanese Heart Journal