Key result
The myocardial performance index in cats is independent of heart rate and systolic arterial pressure but increases significantly during aortic occlusion (increased afterload).
In healthy cats, the myocardial performance index is independent of heart rate and preload but sensitive to changes in afterload.
MPI afterload-sensitive in healthy cats; leaves open validation as load-independent index before clinical or research use.
OBJECTIVE: To evaluate the effect of changes in hemodynamics on the myocardial performance index (MPI) in cats. ANIMALS: 6 mixed-breed cats. PROCEDURES: Cats were anesthetized by administration of thiopental sodium; anesthesia was maintained by administration of isoflurane. Systolic arterial pressure and central venous pressure were measured by use of catheters, and heart rate was controlled by right atrial pacing. Afterload was increased by balloon occlusion of the descending aorta, and preload was increased by IV infusion of lactated Ringer's solution at a rate of 40 mL/kg/h. Echocardiography was performed for each condition. RESULTS: Atrial pacing significantly increased heart rate. The MPI did not change with heart rate. Arterial pressure and MPI increased significantly during aortic occlusion. The IV infusion increased fractional shortening but did not change the MPI. Multiple regression analysis revealed that the MPI was not affected by heart rate, systolic arterial pressure, central venous pressure, fractional shortening, or velocity of the E wave. CONCLUSIONS AND CLINICAL RELEVANCE: The MPI can be used to assess cardiac function in healthy cats. The MPI is independent of heart rate and systolic arterial pressure but is sensitive to changes in afterload.
No takes yet. Share an insight, caveat, or question.
Hori et al. (2007) studied Healthy (n=6). Hemodynamic alterations (atrial pacing, aortic occlusion, IV fluid infusion) vs. Baseline conditions was evaluated on Myocardial performance index (MPI). The myocardial performance index in cats is independent of heart rate and systolic arterial pressure but increases significantly during aortic occlusion (increased afterload).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: