Answers are grounded in this paper and cite their sources.
Oxygen is commonly administered in hospitals, with poor adherence to treatment recommendations. We conducted a multicentre randomised controlled study in patients admitted to the emergency department requiring O 2 ≥3 L·min −1 . Patients were randomised to automated closed-loop or manual O 2 titration during 3 h. Patients were stratified according to arterial carbon dioxide tension ( P aCO 2 ) (hypoxaemic P aCO 2 ≤45 mmHg; or hypercapnic P aCO 2 >45–≤55 mmHg) and study centre. Arterial oxygen saturation measured by pulse oximetry ( S pO 2 ) goals were 92–96% for hypoxaemic, or 88–92% for hypercapnic patients. Primary outcome was % time within S pO 2 target. Secondary endpoints were hypoxaemia and hyperoxia prevalence, O 2 weaning, O 2 duration and hospital length of stay. 187 patients were randomised (93 automated, 94 manual) and baseline characteristics were similar between the groups. Time within the S pO 2 target was higher under automated titration (81±21% versus 51±30%, p<0.001). Time with hypoxaemia (3±9% versus 5±12%, p=0.04) and hyperoxia under O 2 (4±9% versus 22±30%, p<0.001) were lower with automated titration. O 2 could be weaned at the end of the study in 14.1% versus 4.3% patients in the automated and manual titration group, respectively (p<0.001). O 2 duration during the hospital stay was significantly reduced (5.6±5.4 versus 7.1±6.3 days, p=0.002). Automated O 2 titration in the emergency department improved oxygenation parameters and adherence to guidelines, with potential clinical benefits.
No takes yet. Share an insight, caveat, or question.
L’Her et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: