Answers are grounded in this paper and cite their sources.
Time and radially resolved vacuum-ultraviolet spectra from an argon gas-puff Z pinch have been obtained using a grazing incidence spectrometer with gated microchannel plates curved to the Rowland circle. Most of the 50–300-Å radiation is emitted from a dense core (r≊0.4 mm, ne≳1019 cm−3, Te≊150 eV) which forms when the plasma assembles on the axis.
No takes yet. Share an insight, caveat, or question.
Marrs et al. (1983) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: