Key result
Global 11C-hydroxyephedrine retention was a significant predictor of all-cause mortality in patients with left ventricular dysfunction, with a.762 per unit increase.
Why the study?
Does low global 11C-HED retention on PET imaging predict all-cause death in Japanese patients with left ventricular dysfunction?
Observational (n=60)
No
Does low global 11C-HED retention on PET imaging predict all-cause death in Japanese patients with left ventricular dysfunction?
Low global 11C-HED retention on PET imaging is an independent predictor of all-cause mortality in patients with left ventricular dysfunction, highlighting the prognostic value of assessing cardiac sympathetic neuronal integrity.
Answers are grounded in this paper and cite their sources.
May aid mortality risk stratification in LV dysfunction; hypothesis-generating and requires prospective validation before practice change.
OBJECTIVES: The aim of this study was to determine whether (11)C-hydroxyephedrine ((11)C-HED) can predict adverse events including all-cause death in Japanese patients with left ventricular (LV) dysfunction. BACKGROUND: Although (11)C-HED PET has been used to assess cardiac sympathetic innervation in various disease conditions, data on their prognostic value are limited. METHODS: Sixty patients (mean LVEF, 42 ± 14 %) with LV dysfunction (42 ischemic and 18 non-ischemic heart disease) underwent (11)C-HED PET. Myocardial retention was calculated for (11)C-HED PET as a measure of cardiac sympathetic neuronal integrity. Statistical analysis was performed using Cox proportional hazards regression and log-rank test. RESULTS: Thirteen deaths (7 cardiac and 6 non-cardiac deaths) occurred during a mean follow-up period of 33 ± 23 months. The patients with death were associated with significantly lower (11)C-HED retention (7.1 ± 2.1 vs 9.0 ± 2.4, p = 0.015) than those without death. The hazard ratio for global (11)C-HED retention per unit (/min) was 0.762 (p = 0.039), which remained significant in multivariate analysis. When the patients were divided into the high (≥8.5) and low (<8.5) (11)C-HED retention groups, the low (11)C-HED retention group was associated with significantly poorer survival than the high (11)C-HED retention group (p = 0.004). CONCLUSION: The low global (11)C-HED retention is a marker of poor overall survival in patients with LV dysfunction in this study.
No takes yet. Share an insight, caveat, or question.
Fujita et al. (2016) conducted an observational in Left ventricular dysfunction (n=60). Global 11C-hydroxyephedrine (11C-HED) retention vs. Lower vs higher retention was evaluated on All-cause death (HR 0.762, 95% CI 0.580-0.986, p=0.039). Global 11C-hydroxyephedrine retention was a significant predictor of all-cause mortality in patients with left ventricular dysfunction, with a.762 per unit increase.
Synapse has enriched 10 related papers. Consider them for comparative context: