Two new methods for high-resistance connection (HRC) diagnosis in induction motor (IM) drives are presented in this effort. These automatic offline methods are based on a signal injection strategy applied to the IM at standstill. By measuring the voltage in the machine neutral point and phase currents, it is possible to detect and isolate connection problems. Experimental results showing a good sensitivity to HRCs and immunity to symmetrical stator resistance variations were obtained in a laboratory setup.
No takes yet. Share an insight, caveat, or question.
Barrera et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: