This is the authors' abstract. We don't add key points for this paper.
Our YBa2Cu3O7−x thin-film magnetometer consists of a dc superconducting quantum interference device with bi-epitaxial Josephson junctions, fabricated on one chip, and a flux transformer with a multiturn input coil, fabricated on a second chip. Photolithographic processing is used to pattern all layers. The magnetometer operates in a flux-locked loop at temperatures up to 81 K, with the flux transformer improving the magnetic field sensitivity by a factor of 83±3. The low-frequency rms magnetic field noise scales approximately as 1/f1/2, where f is the frequency, with a magnitude of 0.6 pT Hz−1/2 at 10 Hz and 0.09 pT Hz−1/2 at 1 kHz with the magnetometer immersed in liquid N2.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Miklich et al. (1991) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: