Key result
Electroanatomical mapping fails to fully reproduce CT-derived left atrial anatomy, achieving ~81% geometric similarity.
Why the study?
Agreement between CT and electroanatomical mapping for left atrial geometric quantification in atrial fibrillation remains incompletely characterized.
Does electroanatomical mapping accurately reproduce left atrial geometry compared to computed tomography in patients undergoing first-time catheter ablation for atrial fibrillation?
Observational (n=211)
Does electroanatomical mapping accurately reproduce left atrial geometry compared to computed tomography in patients undergoing first-time catheter ablation for atrial fibrillation?
Electroanatomical mapping provides a rapid intraprocedural approximation of left atrial geometry but does not fully reproduce CT-derived anatomy, serving as a complementary rather than substitute modality.
May limit EAM reliance for LA geometry in AF ablation; leaves open prospective validation against CT.
BACKGROUND: Atrial fibrillation (AF) involves heterogeneous remodelling of the left atrium (LA), making accurate geometric quantification clinically relevant. CT is the reference standard for anatomical assessment, whereas electroanatomical mapping (EAM) provides intraprocedural reconstruction with electrophysiological information. However, agreement between both modalities remains incompletely characterized. METHODS: We retrospectively analyzed 211 patients undergoing first-time catheter ablation with pre-procedural CT imaging. LA volume, surface area, and sphericity were derived from CT and EAM. A common ellipsoidal model was fitted to both datasets for comparison via semi-axes (a, b, c). Agreement was assessed using Pearson correlation and Bland-Altman analysis. Geometric differences were quantified using RMS radial differences and Dice similarity on both original meshes and ellipsoidal approximations. RESULTS: , 9.6 %), with slight underestimation of sphericity (-0.01). RMS radial differences were higher for original meshes than ellipsoidal approximations (0.14 vs 0.08), while Dice similarity was higher for ellipsoids than original geometries (0.89 IQR [0.85-0.91] vs 0.81 IQR [0.77-0.83]). CONCLUSIONS: EAM provides a rapid intraprocedural approximation of left atrial geometry but does not fully reproduce CT-derived anatomy. While global shape is partially preserved, systematic scale differences and local discrepancies persist, supporting its role as a complementary rather than substitute modality.
No takes yet. Share an insight, caveat, or question.
Moriones et al. (2026) conducted an observational in Atrial fibrillation (n=211). Electroanatomical mapping (EAM) vs. Computed tomography (CT) was evaluated on Geometric differences quantified using RMS radial differences and Dice similarity. Electroanatomical mapping does not fully reproduce CT-derived left atrial anatomy, yielding a Dice similarity of 0.81 for original geometries and 0.89 for ellipsoidal approximations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: