Key result
Remote photoplethysmography estimated heart rate with a mean absolute error of 3 bpm across all participants, with no significant performance decrease observed across different skin tone groups.
Why the study?
There is concern regarding potential demographic bias in contactless vital sign monitoring, particularly regarding the accuracy of remote monitoring across different skin tone groups.
Does remote photoplethysmography (rPPG) accurately estimate heart rate and heart rate variability compared to contact PPG across different skin tones?
Cross-Sectional (n=90)
Does remote photoplethysmography (rPPG) accurately estimate heart rate and heart rate variability compared to contact PPG across different skin tones?
Remote photoplethysmography can accurately estimate heart rate and heart rate variability without bias across different skin tones, offering a reliable contactless monitoring solution.
Answers are grounded in this paper and cite their sources.
Supports unbiased contactless HR monitoring across skin tones; hypothesis-generating pending validation in clinical populations.
Background Many research studies seek to improve vital sign monitoring to enhance the conditions under which doctors and caregivers track patients ‘ health. Non-invasive and contactless monitoring has emerged as an optimal solution for this problem, with telemedicine, self-monitoring, and wellbeing tools being the next generation of technology in the biomedical field. However, there is worldwide concern about the general purpose and bias towards a certain demographic group of these techniques. In particular, skin tone and the accuracy of monitoring dark skin tone groups have been key questions among researchers, with the lack of results and studies contributing to this uncertainty. Methods This paper proposes a benchmark for remote monitoring solution against a medical device across different skin tone people. Around 330 videos from 90 different patients were analyzed, and Heart Rate and Heart Rate Variability were compared across different subgroups. The Fitzpatrick scale (1-6) was used to classify participants into three skin tone groups: 1 and 2; 3 and 4; 5 and 6. Results The results showed that our proposed methodology was able to estimate heart rate with a mean absolute error of 3 bpm across all samples and subgroups. Moreover, for Heart Rate Variability (HRV) metrics, we achieved the following results, in terms of Mobility Assistive Equipment (MAE): HRV-IBI (Inter-Beat-Interval) of 10 ms; HRV-SDNN (Standard Deviation of Normal to Normal heartbeats) of 14 ms and HRV-RMSSD (Root Mean Square of Successive Differences between normal heartbeats) of 22 ms. No significant performance decrease was found for any skin tone group, and there was no error trend towards a certain group. Conclusions The study showed that our methodology meets acceptable agreement levels for the proposed metrics and is well-suited for users who want to understand their general health and wellness. Furthermore, the experiments showed that skin tone had no impact on the results, which remained within the same range across all groups.
No takes yet. Share an insight, caveat, or question.
Talukdar et al. (2023) conducted a cross-sectional in Healthy (vital sign monitoring) (n=90). Remote photoplethysmography (rPPG) vs. Contact pulse oximeter (PPG) was evaluated on Heart Rate Mean Absolute Error (MAE) (MAE 3 bpm). Remote photoplethysmography estimated heart rate with a mean absolute error of 3 bpm across all participants, with no significant performance decrease observed across different skin tone groups.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: