The design and evaluation of a backscatter-absorption gas-imaging sensor that operates in a pulsed mode is described. It is capable of video visualization of natural gas leaks. Its development was motivated by the need for a methane imaging system to operate at ranges and sensitivities useful to the natural gas industry. The imager employs pulsed laser illumination at a repetition rate of 30 Hz and an average power of ~150 mW to image gas at standoff ranges of as long as 100 m, using a backscatter target with a reflectivity of 0.016 sr(-1). This is a tenfold improvement over an earlier raster-scanned imager. Natural gas leaks as small as 1.6 x 10(-4) standard liters/s [equal to 0.02 standard cubic feet per hour (scfh)] were imaged at short ranges; leaks as low as 7.9 x 10(-4) standard liters/s (0.1 scfh) were observed at long ranges. Data are compared with model predictions, and potential extensions to a fieldable prototype are discussed. The optimization of a direct-injection focal-plane array for detecting short (nanosecond) laser pulses is described.
No takes yet. Share an insight, caveat, or question.
Kulp et al. (1998) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: