Answers are grounded in this paper and cite their sources.
This case highlights a rare mechanical complication of CPR, causing an extreme acute bend and new stenotic lesion in a recently stented right coronary artery.
A 65-year-old man, post coronary artery bypass surgery presented with inferior non-ST-segment elevation myocardial infarction. Coronary angiography (CAG) revealed native coronary artery disease with patent saphenous venous grafts to the left anterior descending and obtuse marginal arteries. The non-grafted right coronary artery (RCA) demonstrated critical stenoses (figure 1A). After percutaneous coronary intervention (PCI) to the RCA, using drug-eluting stents he had a vasovagal syncope that led to cardiac arrest (figure 1B,C). Cardiopulmonary resuscitation (CPR) could restore the sinus rhythm. Under the previously implanted stents, repeat CAG revealed a new stenotic lesion and an extreme acute bend of the distal segment. Intracoronary vaso-dilators did not improve the lesion which ruled out the possibility of coronary vasospasm (figure 1D). As guidewire did not cross the de novo lesion, we were unable to conduct an intravascular ultrasound examination. He was treated conservatively as there was TIMI III flow with no symptoms and stable hemodynamically.
No takes yet. Share an insight, caveat, or question.
Jariwala et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: