Auger and electron spectroscopy for chemical analysis (ESCA) data of TiNx were analyzed as a function of film composition as established by Rutherford backscattering spectrometry (RBS). The overlap of the N(KVV) and Ti(LMM) Auger transitions necessitated the assessment of two methods previously proposed for the derivative spectra. These results were compared with peak height and peak area measurements (after background subtraction) of the well‐separated N(1s) and Ti(2p) ESCA photoemissions. Neither the Auger nor the ESCA N/Ti intensity ratios scaled linearly with the N/Ti compositional ratios determined by RBS, especially for low nitrogen content. This behavior most likely results from ion‐bombardment‐induced losses of nitrogen in those phases with dissolved nitrogen rather than from an increased satellite emission in the Ti(2p) spectra from the near‐stoichiometric nitride. In terms of precision and analysis speed, the Auger peak‐to‐peak quantification methods are preferred over ESCA quantification. In the near‐stoichiometric phase (N/Ti≊1), RBS analysis shows higher sensitivity to nitrogen compositional changes than either ESCA or Auger.