Key result
Simple Doppler variables derived from transmitral and pulmonary venous flow by transesophageal echocardiography predicted elevated pulmonary artery occlusion pressure in mechanically ventilated patients.
Why the study?
Does echocardiography provide reliable estimation of pulmonary artery occlusion pressure compared to invasive measurement in critically ill patients?
Does echocardiography provide reliable estimation of pulmonary artery occlusion pressure compared to invasive measurement in critically ill patients?
Noninvasive PAOP estimation by echocardiography is a useful tool in critically ill patients, though invasive measurement is still required when exact values are needed.
Answers are grounded in this paper and cite their sources.
May aid noninvasive PAOP estimation in ventilated patients; leaves open prospective validation versus catheterization.
The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.
No takes yet. Share an insight, caveat, or question.
Gorazd Voga (2008) conducted an editorial in Acute lung injury and critical illness. Transesophageal echocardiography (TEE) Doppler variables vs. Invasive pulmonary artery catheterization (PAOP > 18 mmHg) was evaluated on Prediction of pulmonary artery occlusion pressure (PAOP) > 18 mmHg. Simple Doppler variables derived from transmitral and pulmonary venous flow by transesophageal echocardiography predicted elevated pulmonary artery occlusion pressure in mechanically ventilated patients.