This is the authors' abstract. We don't add key points for this paper.
Seven hundred and fifty-seven consecutive patients undergoing a midline abdominal incision were stratified according to age, sex, type of operation and degree of operative contamination and were randomly allocated to mass closure of the abdominal wall with continuous 4 metric polydioxanone (PDX; 374 patients) or continuous 4 metric polypropylene (PPL; 383 patients). Wound infection was less common with PDX (PDX 3.5 per cent; PPL 7.0 per cent; P less than 0.05) and there was one dehiscence in each group. The incidence of defective wounds in patients surviving 1 year was similar (7.7 per cent PDX; 9.7 per cent PPL) but the PPL suture had to be removed because of persisting wound pain or sinus formation in five patients. PDX is the preferred suture material for closure of midline abdominal incisions.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Krukowski et al. (1987) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: