Key result
The Atrial Fibrillation Self-Care Scale-10 (AF-SCS-10) demonstrated good internal consistency (reliability coefficient 0.87) and a three-factor structure explaining 79.30% of the total variance.
Why the study?
Existing tools do not capture all critical factors of AF self-care and have limited evidence of reliability and validity.
Does the AF-SCS-10 provide a valid and reliable measure of self-care in patients with chronic atrial fibrillation?
Cross-Sectional (n=290)
Does the AF-SCS-10 provide a valid and reliable measure of self-care in patients with chronic atrial fibrillation?
Effect estimate: reliability coefficient 0.87
The newly developed AF-SCS-10 provides a valid and reliable multidimensional tool to assess self-care in patients with chronic atrial fibrillation.
Supports preliminary AF-SCS-10 reliability; leaves open need for longitudinal validation before clinical adoption.
BACKGROUND: Patients with atrial fibrillation (AF) require continuous self-care due to possible complications and side effects from treatment. However, existing tools do not capture all of the critical factors of AF self-care and have limited evidence of reliability and validity. AIMS: The aim of this study was to develop and evaluate a new Atrial Fibrillation Self-Care Scale-10 (AF-SCS-10) that assesses disease-specific, multidimensional, person-centered self-care for AF patients in South Korea. METHODS: For this cross-sectional research design, 290 individuals over 20 years of age with a diagnosis of AF for at least three months were recruited. A literature review and in-depth interviews were utilized to identify the scale items. An expert panel evaluated the validity and reliability of a preliminary scale. Exploratory factor analysis and parallel analysis was performed to extract factors; confirmatory factor analysis (CFA) was performed to evaluate fit on the factor structures. Criterion validity was supported by the correlation between AF-SCS-10 and AF quality of life. RESULTS: The internal consistency reliability coefficient was 0.87. Three factors, "self-care knowledge," "self-care behavior," and "self-care resources" were extracted from the exploratory factory analysis, explaining 79.30% of the total variance in the data. The three-factor model was also confirmed by parallel analysis; CFA met the fitness criteria. CONCLUSION: There is preliminary evidence for internal consistency reliability, as well as content and construct validity, for the AF-SCS-10. Future research is needed to confirm the study results using a larger, more culturally diverse sample.
No takes yet. Share an insight, caveat, or question.
Son et al. (2020) conducted a cross-sectional in Atrial fibrillation (n=290). Atrial Fibrillation Self-Care Scale-10 (AF-SCS-10) was evaluated on Internal consistency reliability and factor structure (reliability coefficient 0.87). The Atrial Fibrillation Self-Care Scale-10 (AF-SCS-10) demonstrated good internal consistency (reliability coefficient 0.87) and a three-factor structure explaining 79.30% of the total variance.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: