Key result
Postdialysis volume expansion, evaluated by extracellular water to total body weight combined with left ventricular volume, predicted intradialytic hypertension (AUC 0.752; 95% CI 0.613-0.896).
Why the study?
Does volume state assessed by bioelectrical impedance and echocardiography predict intradialytic hypertension in maintenance hemodialysis patients?
Cross-Sectional (n=131)
No
Does volume state assessed by bioelectrical impedance and echocardiography predict intradialytic hypertension in maintenance hemodialysis patients?
Effect estimate: AUC 0.752 (95% CI 0.613-0.896)
Post-dialysis volume expansion, assessed by bioelectrical impedance and echocardiography, is an important risk factor for the development of intradialytic hypertension.
May aid risk stratification in hemodialysis patients; hypothesis-generating for volume-targeted interventions in prospective studies.
Although intra-dialytic hypertension (IDH) has been noted in clinical settings for many years, its pathogenesis remains unclear. In this cross-sectional study, we analyzed IDH incidence in our center and the correlation between postdialysis volume state and IDH. One hundred thirty-one maintenance hemodialysis (MHD) patients were enrolled in our study, and bioelectrical impedance (BIA) and echocardiography (ECG) were recorded. In addition, demographic data were collected, and laboratory examinations were conducted. The patients were grouped into four groups according to the change in systolic blood pressure (SBP) between predialysis and postdialysis. The incidence of IDH was 10.7%. The proportion of extracellular water to total body weight (ECW/TW), as evaluated by BIA, was significantly higher in the IDH group than in the other three groups both in pre-and post-dialysis. In particular, postdialysis SBP was highest in the highest tertile interval of ECW/TW. In addition, among the four groups, left ventricular volume (LVV) was highest in the IDH group. Binary logistic analyses revealed that predialysis SBP, postdialysis ECW/TW and LVV were independent risk factors of intradialytic hypertension. When predicting IDH, the AUC of the ROC curve was higher for ECW/TW combined with LVV (0.752, 95% CI 0.613-0.896) than for either LVV or ECW/TW alone. Our study further showed that post-dialysis volume expansion is an important factor for the development of IDH.
No takes yet. Share an insight, caveat, or question.
Ren et al. (2017) conducted a cross-sectional in Maintenance hemodialysis (n=131). Postdialysis volume expansion (ECW/TW and LVV) vs. Lower volume states was evaluated on Prediction of intradialytic hypertension (AUC 0.752, 95% CI 0.613-0.896). Postdialysis volume expansion, evaluated by extracellular water to total body weight combined with left ventricular volume, predicted intradialytic hypertension (AUC 0.752; 95% CI 0.613-0.896).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: