Why the study?
Whether patients with end-stage heart failure and continuous-flow left ventricular assist devices derive mortality benefits from implantable cardioverter-defibrillators remains controversial.
Does an active implantable cardioverter-defibrillator reduce all-cause mortality in advanced heart failure patients with a continuous-flow left ventricular assist device?
Does an active implantable cardioverter-defibrillator reduce all-cause mortality in advanced heart failure patients with a continuous-flow left ventricular assist device?
Active ICDs do not significantly improve all-cause mortality or survival to transplant compared to inactive/no ICD in patients with continuous-flow LVADs, despite a high burden of appropriate shocks.
Active ICDs confer no mortality or transplant survival benefit in cf-LVAD recipients; challenges routine use and supports dedicated RCTs.
INTRODUCTION: Implantable cardioverter-defibrillator (ICD) in patients with heart failure with reduced ejection fraction reduces mortality secondary to malignant arrhythmias. Whether end-stage heart failure (HF) with continuous-flow left ventricular assist device (cf-LVAD) derive similar benefits remains controversial. METHODS: We performed a systematic literature review and meta-analysis of all published studies that examined the association between active ICDs and survival in advanced HF patients with cfLVAD. We searched PubMed, Medline, Embase, Ovid, and Cochrane for studies reporting the association between ICD and all-cause mortality in advanced HF patients with cfLVAD. Mantel-Haenszel risk ratio (RR) random-effects model was used to summarize data. RESULTS: =34%) between Active ICD and inactive/no ICD groups, respectively. Additionally, 27.5% received appropriate ICD shocks, while 9.5% received inappropriate ICD shocks. No significant difference was observed in terms of any complications between the two groups. CONCLUSIONS: All-cause mortality, the likelihood of survival to transplant, and worsening RV failure were not significantly different between active ICD and inactive/no ICD in cf-LVAD recipients. A substantial number of patients received appropriate ICD shocks suggesting a high-arrhythmia burden. The risks and benefits of ICDs must be carefully considered in patients with cf-LVAD.
No takes yet. Share an insight, caveat, or question.
A 2020 study studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: