Key result
ICD use fails to improve survival in advanced heart failure patients with CF-LVADs.
Why the study?
Whether advanced HF patients treated with continuous-flow left ventricular assist devices derive a survival benefit from implantable cardioverter-defibrillators was controversial.
Does ICD implantation improve survival in advanced heart failure patients with continuous-flow left ventricular assist devices?
Meta-Analysis (n=6,416)
Does ICD implantation improve survival in advanced heart failure patients with continuous-flow left ventricular assist devices?
ICD implantation is not associated with improved survival in advanced heart failure patients supported by continuous-flow left ventricular assist devices.
Answers are grounded in this paper and cite their sources.
ICD use may not improve survival in CF-LVAD patients; challenges routine implantation and leaves open need for RCTs.
AbstractAimsImplantable cardioverter-defibrillators (ICDs) implantation in heart failure (HF) patients with reduced ejection fraction improves survival by reducing mortality secondary to arrhythmic events. Whether advanced HF patients treated with continuous-flow left ventricular assist devices (CF-LVADs) derive similar benefit is controversial.Methods and resultsWe searched PubMed, Cochrane Central Register of Controlled Trials, Embase, and Scopus from inception through November 2018 for studies examining the association between ICD implantation and all-cause mortality in patients with advanced HF and CF-LVADs. Analyses were performed using a random-effects model. Hazard ratios (HRs) were calculated with 95% confidence intervals (CIs). Heterogeneity and publication bias were formally assessed, using I2 and funnel plots, respectively. Eight observational studies with a total of 6416 patients (ICD group = 3450, no ICD group = 2966) met inclusion criteria. The majority of patients (84.6%) came from the two largest observational studies. There was no difference in mortality in the ICD and no ICD groups (HR 0.96, 95% CI 0.73–1.27, P = 0.79, I2 = 42%), and ICD implantation post-CF-LVAD was not associated with an improvement in mortality (HR 0.87, 95% CI 0.48–1.57, P = 0.64, I2 = 0%). Additionally, there was no significant difference in the likelihood of transplantation (HR 1.10, 95% CI 0.93–1.30, P = 0.28, I2 = 26%) or non-mortality adverse events between the two groups.ConclusionImplantable cardioverter-defibrillator use was not associated with improved survival in advanced HF patients with CF-LVADs. These findings underscore the need to formally study the efficacy of ICDs in this population in a dedicated randomized controlled study.
No takes yet. Share an insight, caveat, or question.
Elkaryoni et al. (2019) conducted a meta-analysis in Advanced heart failure with continuous-flow left ventricular assist devices (CF-LVADs) (n=6,416). Implantable cardioverter-defibrillators (ICDs) vs. No ICD was evaluated on all-cause mortality (HR 0.96, 95% CI 0.73-1.27, p=0.79). Implantable cardioverter-defibrillator use was not associated with improved survival compared to no ICD in advanced heart failure patients with CF-LVADs.
Synapse has enriched 10 related papers. Consider them for comparative context: