A performance analysis of three-phase and dual three-phase (DTP) induction pulsewidth modulation (PWM) inverter-fed motor drives is conducted in this paper. The focus is on the efficiency performance of high-frequency DTP machines compared to their three-phase counterparts in low/medium power applications. For this purpose, a DTP machine, having two sets of stator three-phase windings spatially shifted by 30 electrical degrees (asymmetrical six-phase winding configuration), was tested for both six-phase and three-phase winding configurations under the same magnetic conditions. Simulation and experimental results are presented to evaluate the efficiency performance of three-phase and dual-three induction motor drives employing PWM voltage source inverters.
No takes yet. Share an insight, caveat, or question.
Boglietti et al. (2008) studied this question.