This editorial supports the use of generalized transfer functions for noninvasive central aortic pressure estimation while cautioning against inappropriate assumptions of radial artery form factors.
See the Original Article on page 169. In this issue of the Journal, Laugesen et al.1 provide an assessment of the SphygmoCor device for generating central aortic pressure noninvasively from the radial artery pressure waveform in diabetic subjects. Clearly, it is important for potential users to be comfortable with a system such as this,2 especially when the core patent (of mathematical transfer function use under different circumstances) has expired, other devices that use similar technology are now available, and all such devices are being used much more frequently than in the past and in different clinical conditions. The original method was approved for SphygmoCor by the US Food and Drug Administration (FDA) more than 10 years ago under K002742 (1 May 2001) for invasive use and K012487 (21 February 2002) for noninvasive use. Approval for invasive use was based on near identity of central aortic pressure waveforms with waveforms generated from simultaneously recorded invasive radial artery waveforms using carefully matched manometers3 and according to American Association for the Advancement of Medical Instrumentation (AAMI) criteria.4 These findings have repeatedly been confirmed5, including in Laugeson et al.’s study of diabetic patients.1 The noninvasive method for generating central aortic pressure waveforms, also approved by the FDA under K012487, used the same transfer function but depended on accuracy of the radial pressure waveform recorded under theoretically appropriate conditions using applanation tonometry and a validated Millar device, which had been modified from the classic Millar micromanometer catheter system.6 Kelly et al.7 confirmed identity of the invasive and noninvasive waveforms under ideal conditions from the radial artery. (Similar identity could not be achieved in measurement of brachial or carotid pressure waves, where the arterial surface cannot be applanated (flattened) reliably.)5 The FDA had a problem in acceptance of the noninvasive generation of the aortic pressure wave because it did not recognize central aortic pressure as being of clinical value nor did it recognize mean pressure as being of clinical value in previous studies. The FDA was well aware of systematic but large and variable differences between intra-arterial brachial pressure and brachial pressure measured simultaneously by cuff in the contralateral arm.5 With the accepted clinical standard the cuff sphygmomanometer and brachial systolic pressure recorded therefrom, the FDA accepted the central aortic pressure values when the radial systolic peak and diastolic nadir were calibrated from the brachial cuff values and recorded according to American Heart Association guidelines.8 This decision considered the small difference between brachial and radial systolic or diastolic pressures to be trivial when measured invasively.9,10 Reference to brachial systolic and diastolic cuff pressures by the FDA as the gold standard for reference and calibration is not appreciated by many, especially clinical pharmacologists who use the SphygmoCor or similar devices, but it is sensible and builds on the clinical use of cuff sphygmomanometry over the past century. Central aortic pressure waves so recorded are what central aortic pressure would be in an individual if brachial cuff recordings were accurate. The FDA had no particular interest or trust in central aortic pressure measured invasively because there was no convention or use for this. The FDA considered that value of central pressure could emerge from use of the technique but that such must be demonstrated as incremental to brachial cuff values because these would remain the gold standards for the foreseeable future. Findings of Laugeson et al.1 in this issue are consistent with use of SphygmoCor and similar devices, which generate the aortic pressure waves from applanation tonometry at the radial site and with radial waveforms calibrated to brachial cuff pressures. Their findings from invasive data of systolic blood pressure (−2.3±6.1mm Hg) are well within the limits set by the AAMI and the FDA (mean ≤ 5 SD ≤ 8mm Hg) and as reported by Pauca et al.3 Findings confirm value of the generalized transfer function when applied to diabetic subjects. Apparent need for a different transfer function in diabetics was suggested in previous literature, but that suggested by Hope et al. (Laugesons’ reference 11) contained mathematical error11 that induced wild pressure fluctuation and had higher frequency radial components precede the corresponding aortic fluctuations (suggesting flow toward rather than from the heart).5 Transfer functions now used by others12,13 are very similar to those originally described by our group in Sydney, Australia,14 and this was first verified by Chen and colleagues at Johns Hopkins12 in 1997. We cannot recommend the method suggested by Laug eson et al.1 for assumption of radial artery form factor (FF) as 0.40 for the radial artery. This does not conform to FDA recommendations nor to hemodynamic principles.5,15 Such assumption would have mean pressure estimated in all arteries of all persons as diastolic pressure + 40% of pulse pressure, whereas a previous rule of thumb was to estimate mean pressure as diastolic pressure + 33% of pulse pressure.5,15 Radial mean pressure can be calculated for any individual from the radial artery pressure wave by integrating (averaging) over the whole cycle.5 Likewise, the aortic pressure wave can be averaged over the whole cycle to generate mean pressure when peak and nadir of the wave are known. This is done in SphygmoCor and similar systems, where the only assumption is that mean pressure is identical (rather than within 1mm Hg3) at the 2 sites. It is not surprising that authors find better correlation between their synthesized and directly measured values of aortic systolic and diastolic pressure when using an FF of 40%, but this is a consequence of brachial and central systolic invasive pressure being consistently higher than brachial cuff pressure and outside AAMI limits and FDA requirements. The FDA position on this issue and approval of SphygmoCor use under K002742 has been described above; the authors’ suggestions are unlikely to find favor in the United States. A final comment is warranted on use of a generalized transfer function in physiological studies and medical practice because this is unfamiliar to many users of medical devices and has intrigued the authors over their professional lifetime. A generalized transfer function is a mathematical method for transforming one frequency-dependent variable into another.5 Such devices are widely used in acoustics and in diverse engineering fields. The device characterizes the properties of a system such that the differences in variables, such as pressure and pressure at 2 sites (or pressure and flow at the same site), can be described in the frequency domain as modulus (amplitude) and phase (delay). It carries the assumption that the system is linear (i.e., that nonlinearities are sufficiently small to be neglected as a first approximation). The first general use of transfer functions in cardiovascular research was by McDonald16 and Womersley17 to characterize the relationship between pulsatile pressure gradient and flow in an arterial segment. Womersley showed that nonlinearities in the equations of motion applied to such a site were sufficiently small to be neglected to a first approximation.5 This encouraged Taylor’s studies to vascular impedance as a hydraulic description of a vascular bed to include wave travel and wave reflection in the bed, as well as resistance in the distal microvasculature.18–20 Results were extraordinarily consistent and led to the use of transfer function of pressure at 2 sites to characterize the vascular bed and the use of the derived transfer function to generate the central (aortic) waveform from the peripheral (radial) pressure waveform.5,14 This approach has been very useful as described above and as applied by Laugesen et al.1 in this issue. Those who use a transfer function to generate the central pressure from the peripheral pressure wave can draw comfort from the fact that the process is easy to use in a modern instrument, that transfer functions are virtually the same in contemporary commercial devices used to characterize properties of the upper limb arteries, that the transfer function is little affected by age, blood pressure, heart rate, or disease, and that such devices5 are providing outcome data from patient groups and information in individuals that is superior to that available with other methods, including the basic cuff sphygmomanometer (which, nonetheless, remains essential to calibration). The problems that remain include use of tonometry at sites such as the brachial artery where applanation cannot reliably be achieved and calibration. Better understanding and use of a valuable asset hopefully comes from the perspective provided here. We thank the authors and editors for providing the opportunity. Dr O’Rourke is a founding director of AtCor Medical P/L, manufacturer of pulse wave analysis system, SphygmoCor, and of Aortic Wrap P/L, developer of methods to reduce aortic stiffness, and is a consultant to Novartis and Merck. Dr Adji declared no conflict of interest.
No takes yet. Share an insight, caveat, or question.
O'Rourke et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: