Answers are grounded in this paper and cite their sources.
Simulation modeling reveals coupled solar thermal and heat pump heating lowers energy demand in office buildings, indicating a viable strategy for low-carbon climate control.
PV/T collectors and Air Source Heat Pump (ASHP) are widely studied for building heating, but solar intermittency and ASHP low-temperature frosting limit their large-scale deployment. A novel PV/T-ASHP coupled heating system is proposed to cut building carbon emissions and relieve ASHP performance degradation in cold zones. Circulating water cools PV/T panels to boost power generation, and the warmed water preheats ASHP evaporator inlet air to reduce frosting and defrosting frequency. With a Xi’an office building as the research object, validated TRNSYS 18.0 models are established for comparative analysis with conventional systems and cross-climate evaluation in Xi’an, Beijing, Shanghai and Chengdu. Results show the new system lifts PV/T combined efficiency by 17.56%, reduces energy consumption by 19.9%, and achieves an average COP of 3.2. Across climate zones, its COP rises 11.5–24.6% and 50-year carbon emissions fall 16.4–26.2%, supporting low-carbon heating promotion for office buildings.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: