Key result
Contact force-sensing catheters linked to shorter fluoroscopy time but longer procedure duration in catheter ablation.
Why the study?
The study was designed to systematically evaluate the impact of contact force-sensing catheters on fluoroscopy and procedure time in interventional electrophysiology.
Does the use of contact force-sensing catheters reduce fluoroscopy time and procedure time compared to conventional catheters in patients undergoing electrophysiological ablation procedures?
Cross-Sectional (n=1,425)
Yes
Does the use of contact force-sensing catheters reduce fluoroscopy time and procedure time compared to conventional catheters in patients undergoing electrophysiological ablation procedures?
In routine European electrophysiology practice, contact force-sensing catheters significantly reduce fluoroscopy exposure during atrial ablations and shorten both procedure and fluoroscopy durations specifically for pulmonary vein isolations, though they prolong right atrial and ventricular procedure times.
Answers are grounded in this paper and cite their sources.
Associated with lower fluoroscopy time in atrial ablations; leaves open net benefit given longer procedures in right atrial and ventricular cases.
This multicenter European survey systematically evaluated the impact of using contact force-sensing catheters (CFSCs) on fluoroscopy and procedure time in interventional electrophysiology. Data from 25 participating centers were collected and analyzed, also considering important confounders. With the use of CFSCs, fluoroscopy time was reduced for right- and left-sided atrial ablations (median −6.4 to −9.6 min, p < 0.001 for both groups), whereas no such effect could be found for ventricular ablations. Moreover, the use of CFSCs was associated with an increase in procedure time for right-sided atrial and ventricular ablations (median +26.0 and +44.0 min, respectively, p < 0.001 for both groups), but not for left-sided atrial ablations. These findings were confirmed independent of career level and operator volume, except for very highly experienced electrophysiologists, in whom the effect was blunted. In the subset of pulmonary vein isolations (PVIs), CFSCs were shown to reduce both fluoroscopy and procedure time. In conclusion, the use of CFSCs was associated with a reduced fluoroscopy time for atrial ablations and an increased procedure time for right atrial and ventricular ablations. These effects were virtually independent of the operator experience and caseload. When considering only PVIs as an important subset, CFSCs were shown to reduce both fluoroscopy and procedure time.
No takes yet. Share an insight, caveat, or question.
Fiedler et al. (2022) conducted a cross-sectional in Cardiac arrhythmias undergoing interventional electrophysiological ablation (n=1,425). Contact force-sensing catheters (CFSCs) vs. Conventional ablation catheters without contact force sensing was evaluated on Fluoroscopy time and procedure time (p=<0.001). Contact force-sensing catheters reduced median fluoroscopy time by 6.4 to 9.6 min in atrial ablations but increased median procedure time by 26.0 to 44.0 min in right atrial and ventricular ablations.