The study establishes the force-velocity relationship and series elastic characteristics of hog carotid artery smooth muscle, fitting the data to the Hill equation.
Answers are grounded in this paper and cite their sources.
Provides baseline mechanics for hog carotid smooth muscle; leaves open applicability to human vascular disease or therapies.
The force-velocity and series elastic characteristics of vascular strips from the media of hog carotid arteries were determined using the method of quick release to a known afterload. Shortening velocity was a function of load, and the data could be fitted by a rectangular hyperbola using the Hill equation, (P + a) V = b (P o - P), where P is the load, P o is the maximum isometric force developed at the optimum muscle length (L o ), V is velocity, and a and b are constants. The following dynamic constants were obtained for the electrically stimulated strips: estimated maximum shortening velocity for the unloaded muscle (V max ) = 0.12 L o /sec, b = 0.02 L o /sec, P o = 1.80 kg-wt/cm 2 = 1.76 x 10 6 dynes/cm 2 , and a/P o = 0.18. Maximum power output occurred at a load of 0.28 P o . The stress-strain curve for the series elastic component could be approximated by the simple exponential equation, stress = 0.034e 058 strain . The extension of the series elastic component at P o was 7.2% of L o .
No takes yet. Share an insight, caveat, or question.
Herlihy et al. (1974) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: