Key result
Percutaneous suction thrombectomy using the AngioVac Generation 3 device successfully and safely removed a massive, hypermobile (Type C) right atrial thrombus without complications.
Why the study?
Experience with the management of Type C right atrial thrombi, which are hypermobile but also broad-based, has not been explicitly described in the literature.
Case Report (n=1)
No
AngioVac suction thrombectomy is a safe alternative option for the removal of a Type C, massive, hypermobile right atrial thrombus.
Type C right atrial thrombi may need individualized decisions; leaves open optimal strategies for this hybrid morphology.
BACKGROUND: Right atrial thrombus (RAT) may be managed according to morphology and aetiology, i.e. Type A thrombi ('clot-in-transit', hypermobile) are managed with thrombolytics and surgical embolectomy due to high risk of embolization; Type B thrombi (broad-based, globular) may be managed medically as they will very likely maintain a benign course. Experience with management of a Type C thrombus (hypermobile but also broad-based) has not been explicitly described in the literature. CASE SUMMARY: A 25-year-old man with history of leukaemia with prior right subclavian vein chemoport is found to have massive RAT. Multimodal imaging shows a hypermobile mass attached to the right atrial lateral wall inferior to superior vena cava and prolapsing into right ventricle in diastole. Given the thrombus morphology and likely propagation from subclavian port, risk of catastrophic embolization was deemed high and as such, intervention was indicated. Systemic anticoagulation was considered but deferred due to theoretical risk of dissolving the thrombus stalk leading to embolization. Surgical thrombectomy was offered but the patient declined. Due to evidence for success in RAT, the AngioVac System: Generation 3 (Angiodynamics, Inc., Latham, NY, USA) was chosen for intervention. The RAT was successfully removed without any complication. DISCUSSION: AngioVac suction thrombectomy is a safe alternative option for removal of a Type C, massive, hypermobile RAT.
No takes yet. Share an insight, caveat, or question.
Reddy et al. (2021) conducted a case report in Massive, hypermobile (type C) right atrial thrombus (n=1). AngioVac suction thrombectomy was evaluated on Thrombus removal and procedural complications. Percutaneous suction thrombectomy using the AngioVac Generation 3 device successfully and safely removed a massive, hypermobile (Type C) right atrial thrombus without complications.