Why the study?
Accurate aortic valve annulus sizing is critical for TAVR, and while CTA is standard, 2D- and 3D-TEE are commonly used, warranting evaluation of measurement discrepancies on survival.
Does a discrepancy between TEE and CTA measurements of the aortic annulus affect long-term survival in patients undergoing TAVR?
Does a discrepancy between TEE and CTA measurements of the aortic annulus affect long-term survival in patients undergoing TAVR?
Discrepancies greater than 10% between TEE and CTA measurements of the aortic annulus are associated with decreased long-term survival and higher pressure gradients following TAVR.
Answers are grounded in this paper and cite their sources.
Discrepancies in annular sizing were associated with worse post-TAVR survival; leaves open whether CTA or TEE should guide prosthesis selection.
Introduction: Accurate measurement of the aortic valve annulus is critical for proper valve sizing for the transcatheter aortic valve replacement (TAVR) procedure. While computed tomography angiography (CTA) is the widely-accepted standard, two-dimensional (2D) and three-dimensional(3D) transesophageal echocardiography (TEE) is commonly performed to measure the size of the aortic valve and to verify appropriate seating of prostheses. Methods: Patients undergoing TAVR between 2013-2015 were examined. 2D- and 3D-TEEmeasurements were compared to CTA taken as standard. Patients were followed for at least one year. The presence and effect of discrepancy (defined as a difference of more than 10%) between CTA and TEE measurements on survival were examined. Results: One hundred eighty-five patients (70 men) were included. 2D- and 3D-TEE measurements underestimated the annulus size by -1.49 and -1.32 mm, respectively. Discrepancies > 10% between TEE and CTA methods in estimating the aortic annulus size were associated with a decrease in post implant survival. The peak pressure gradient across the aortic prosthesis measured one year after the implant was higher in patients with an initial discrepancy between 3D-TEE and CTA measurements. In a multivariate cox-regression model, the discrepancy between CTA and 2D-TEE readings and the smaller size of the aortic annular area were the predictors of long-term survival. Conclusion: Both 2D and 3D-TEE underestimate the aortic annulus measurements compared to CTA, with 2D-TEE being relatively more precise than 3D-TEE technology. The presence of a discrepancy between echocardiographic and CTA measurements of the aortic annulus is associated with a lower survival rate.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: