Why the study?
Safe and effective glycemic control in ICU patients is challenging due to hypoglycemia risk and patient variability, prompting clinical evaluation of a new tri-variate stochastic model (STAR-3D).
Does the STAR-3D glycemic control framework improve blood glucose control and safety in ICU patients compared to the original STAR framework?
Does the STAR-3D glycemic control framework improve blood glucose control and safety in ICU patients compared to the original STAR framework?
The STAR-3D glycemic control framework provided safe and effective blood glucose control with high nutrition delivery and no severe hypoglycemia in ICU patients.
Glycemic control (GC) has improved outcomes for intensive care unit (ICU) patients. However, the increased risk of hypoglycemia and glycemic variability due to inter- and intra- patient variability make safe, effective GC difficult. Stochastic TARgeted (STAR) GC framework is a unique, patient-specific, risk-based dosing protocol directly accounting for both inter- and intra- patient variability using a stochastic model of future patient variability. A new tri-variate (3D) stochastic model, developed and validated in virtual trials to provide more accurate future predictions of insulin sensitivity (SI), is clinically evaluated. STAR-3D was implemented as standard care at the Christchurch Hospital ICU, New Zealand, between April 2019 and January 2021. In total, 567 patients (33276 hours) were treated. The overall median [IQR] BG achieved was 6.7 [6.0 7.8] mmol/L with 76% BG in the 4.4-8.0 mmol/L target band. Importantly, there were only 0.3% BG < 4.0 mmol/L (mild hypoglycemia) and no incidence of severe hypoglycemia (BG < 2.2 mmol/L). These outcomes were achieved with median [IQR] 4.0 [2.0 6.0] U/h insulin and median [IQR] nutrition delivery of 99 [80 100]% goal feed (GF). Similar safety and performance BG outcomes were obtained at a per-patient level, suggesting STAR-3D successfully provided safe, effective control for all patients, regardless of patient condition. Compared to the original version of STAR, STAR-3D provided improved safety and efficacy, while achieving higher nutrition delivery. The new 3D stochastic model in STAR-3D provided higher safety and efficacy for all patients in this large clinical trial, despite using higher insulin rates than its predecessor to provide greater nutrition delivery. STAR-3D thus better captured patient-specific condition and variability to provide improved GC outcomes.
No takes yet. Share an insight, caveat, or question.
Uyttendaele et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: